New experimental approach on charging technique of helium surface over rectangular electrodes at cryogenic temperature
نویسندگان
چکیده
We report results on the charging technique of liquid helium surface over rectangular electrodes and maximum sustainable electron density at temperatures above 1 K. Also, thermally activated escape of twodimensional electrons from the potential well has been studied as a function of various parameters like electrons density and temperature. Results provide insights into the charging process of the surface-state electrons and their stability parameters over these electrodes with AC capacitive coupling technique.
منابع مشابه
Accurate characteristics of Helium in nano-channels
This article describes an accurate subPico flowmeter bifurcatedin to liquid and gas flowrates less than 1mol/s for both MEMS/NEMS and cryogenic technology applications. The MEMS/NEMS are described as either two Gauges (instrument), or quartz fluctuating forks, even if the liquid or gas flows through an element, as well as cryogenic technology consisting of arrays of e...
متن کاملAccurate characteristics of Helium in nano-channels
This article describes an accurate subPico flowmeter bifurcatedin to liquid and gas flowrates less than 1mol/s for both MEMS/NEMS and cryogenic technology applications. The MEMS/NEMS are described as either two Gauges (instrument), or quartz fluctuating forks, even if the liquid or gas flows through an element, as well as cryogenic technology consisting of arrays of e...
متن کاملCommissioning of the Heidelberg Cryogenic Trap for Fast Ion Beams (ctf)
We report on the present state of commissioning of the cryogenic electrostatic trap for fast ion beams (CTF) at the Max-Planck-Institut für Kernphysik in Heidelberg. The device has recently passed a cryogenic test, during which the trap was cooled down by 1.8 K superfluid helium. No leaks of the helium supply system were observed, the temperature below 10 K was reached, and the required positio...
متن کاملDesign and construction of a helium purification system using cryogenic adsorption process
One of the most appropriate methods for elimination of trace impurities in helium is cryogenic adsorption process. So, in this study design and construction of cryogenic adsorption helium purification system (3 Nm3.hr-1, 80 bar) carried out using activated carbon as adsorbent at 77K. To evaluation of adsorption dynamics and effect of pressure on elimination of trace impurities, helium purificat...
متن کاملCryogenic effect on dust grain charging in a plasma
Charging mechanism of dust particles in a nonuniform discharge plasma under cryogenic environment is studied theoretically. The plasma density and temperature effects on dust grain charging are investigated with characteristic time scales of density variation and temperature relaxation in consideration. The charge of a dust grain, initially placed in a discharge plasma and cooled to cryogenic t...