Strategies for Film Replacement in Radiography - Films and Digital Detectors in Comparison -

نویسندگان

  • Uwe EWERT
  • Uwe ZSCHERPEL
  • Klaus BAVENDIEK
چکیده

The NDT community has discussed about effective film replacement by Computed Radiography (CR) and the new Digital Detector Arrays (DDA), also known as flat panel detectors, since more than 10 years. Several standards were published by CEN, ASTM and ASME to support the application of phosphor imaging plates in lieu of X-ray film in the year 2005. One of the key concepts is the usage of signal/noise (SNR) measurements as equivalent to the optical density of film and film system class. The radiographic practice with DDAs is not yet described by any standard, but proposals are under discussion. The first qualification standard for DDAs, ASTM E 2597-07, has been published recently. The bad pixel problem has been addressed. Measurement methods were elaborated and tested at BAM for determination of parameters as basic spatial resolution, efficiency, specific material thickness range, contrast sensitivity and image lag. These procedures were used for this study. The achieved image quality is discussed for film replacement by CR and DDAs in weld inspection. New strategies for correct DDA calibration yield an extra ordinary increase of image quality. The contrast sensitivity was enhanced up to 10 times in relation to film radiography. This could not yet be achieved by any other technology. Even restrictions in the spatial resolution, provoked by the individual picture element (pixel) size of the detector, are compensated by the increased contrast sensitivity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vitro Comparison of Conventional Film and Direct Digital Radiography in Proximal Caries Detection

Introduction: Various systems for intraoral digital radiography have been available as an alternative to film–based radiography. In consideration of several advantages of digital radiography such as less patient absorbed dose, manipulation of im‌age quality and elimination of processing, it has been extensively used in different fields of denti‌stry in recent years. The purpose of this study wa...

متن کامل

Quality comparison of direct digital panoramic radiography and computed radiography panoramic

BACKGROUND AND AIM: Digital panoramic X-ray images can be captured using photostimulable phosphors or solid-state detectors (i.e. charge-coupled devices and Flat-Panels). The first category is defined as computed radiography (CR) or semi-direct radiography. The second technology that uses solid-state detectors is known as direct digital radiography (DDR). Both of these technologies have their o...

متن کامل

Strategies for Film Replacement in Radiography - a comparative study -

The NDT community discusses about effective film replacement by Computed Radiography (CR) and Digital Detector Arrays (DDA), also known as flat panel detectors, since more than 10 years. Several standards were published by CEN, ASTM and ASME to support the application of phosphor imaging plates in lieu of X-ray film in the year 2005. The European Community funds the project FilmFree, which supp...

متن کامل

Replacement of Film Radiography by Digital Techniques and Enhancement of Image Quality

New digital detectors were developed for medical applications, which have the potential to substitute the X-ray film. Digital Detector Arrays (DDA: Flat Panel Detectors, Line Detectors) and Imaging Plates (Computed Radiography, CR) allow a fast acquisition of radiographic images with higher dynamic than film. Especially DDA’s allow a radiographic inspection with considerable higher image qualit...

متن کامل

Film Replacement by Digital X-ray Detectors - the Correct Procedure and Equipment

New digital detectors were developed for medical applications, which have the potential to substitute the X-ray film and revolutionise the radiological technique. Digital Detector Arrays (DDA: Flat Panel Detectors, Line Detectors) and Imaging Plates (Computed Radiography) allow a fast detection of radiographic images in a shorter time and with higher dynamic than film applications. Companies re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008