Comparative Study of Peripheral Rim Fixation Using Jumbo Cup in Revisional Hip Arthroplasty

نویسندگان

  • Woo-Lam Jo
  • Young-Wook Lim
  • Jin-Hyung Im
  • Seung-Chan Kim
  • Soon-Yong Kwon
  • Yong-Sik Kim
چکیده

PURPOSE It is challenging procedure to revise acetabular component in acetabulum with severe bone defect or deformity. The jumbo cup is good option for revisional arthroplasty in large bone defect. The purpose of this study is to compare the prognosis of revisional total hip arthroplasty using jumbo cup with peripheral rim fixation and no rim fixation. MATERIALS AND METHODS We included the patients who had performed acetabular revisional total hip arthroplasty from January 2002 to March 2015 in our institute. Total of 51 hips (51 patients) were included. The mean follow up period was 51 months (range, 12 to 154 months) and mean age was 60.7 years (range, 30 to 81 years). We divided into two groups (peripheral rim fixation group and no rim fixation group) by anteroposterior and lateral plain radiograph. We compared survival rate, hip center change and clinical outcomes between two groups. RESULTS There were 37 patients in peripheral rim fixation group and 14 patients in no rim fixation group. There was one patient who had aseptic loosening necessary to re-revision in rim fixation group and 3 patients in no rim fixation group. And one patient had superficial infection in rim fixation group and one patient had periprosthetic fracture in no rim fixation group. Survival rate was higher in the peripheral rim fixation group (97.3%) than no rim fixation group (78.6%, P=0.028). CONCLUSION Based on our findings, peripheral rim fixation might be recommended to improve short-term outcome after revision total hip arthroplasty using jumbo cup.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acetabular Cup Revision

The use of acetabular cup revision arthroplasty is on the rise as demands for total hip arthroplasty, improved life expectancies, and the need for individual activity increase. For an acetabular cup revision to be successful, the cup should gain stable fixation within the remaining supportive bone of the acetabulum. Since the patient's remaining supportive acetabular bone stock plays an importa...

متن کامل

Options for managing severe acetabular bone loss in revision hip arthroplasty. A systematic review.

Revision hip arthroplasty in the presence of severe acetabular bone loss is challenging and requires a solid understanding of current techniques. A literature search of multiple databases applying specific criteria revealed a total of 50 articles of level IV scientific evidence comprising 2415 patients (2480 hips) managed with reinforcement devices (roof-reinforcement rings and anti-protrusio c...

متن کامل

Cotyloplasty in Cementless Total Hip Arthroplasty for an Insufficient Acetabulum

BACKGROUND Cotyloplasty is a technique that involves making a perforation of the medial wall of a shallow acetabulum and then inserting an acetabular cup with the medial aspect of its dome beyond the Kohler line. The purpose of this study was to evaluate the results of cementless total hip arthroplasty (THA) using cotyloplasty with focusing on the amount of medial cup protrusion. METHODS Sixt...

متن کامل

Biomechanical study of the resurfacing hip arthroplasty: finite element analysis of the femoral component.

Finite element analysis was performed using 3-dimensional models to examine the biomechanical characteristics of the femoral component in resurfacing hip arthroplasty. Stress concentration was observed in the cortical bone adjacent to the rim of the prosthesis. Stress shielding was observed in the anterosuperior regions on the cancellous bone cross-sections near the cup rim. These biomechanical...

متن کامل

Challenges of Plate Fixation for Vancouver Type-C Fractures after a Well-Fixed Hip Arthroplasty Femoral Stem

The fixation of distal femoral fractures (Vancouver type-C fractures) following a well-fixed hip arthroplasty femoral stem has become a challenging issue for orthopedic surgeons due to the inter-prosthetic biomechanical effects such as negative, positive, and torsional strain. Surgeons have applied a range of constructs to overcome these difficulties. To minimize the risk of inter-prosthetic fr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 29  شماره 

صفحات  -

تاریخ انتشار 2017