BACKGROUND Measurement of intrapleural pressure is useful during various pleural procedures. However, a pleural manometer is rarely available. OBJECTIVES The aim of this study was to (1) construct an electronic pleural manometer, (2) assess the accuracy of the measurements done with the new device, (3) calculate the costs of the manometer construction and (4) perform an initial evaluation of the device in a clinical setting. METHODS Only widely accessible elements were used to construct the device. A vascular pressure transducer was used to transform pressure into an electronic signal. Reliability of the measurements was evaluated in a laboratory setting in a prospective, single-blind manner by comparing the results with those measured by a water manometer. Functionality of the device was assessed during therapeutic thoracentesis. The cost of the new pleural manometer was calculated. RESULTS We built a small, portable device which can precisely measure intrapleural pressure. The measurement results showed very high agreement with those registered with a water manometer (r = 0.999; p < 0.001). The initial evaluation of the electronic manometer during therapeutic thoracentesis showed it was easy to use. The total time needed for 6 measurements after withdrawal of different volumes of pleural fluid in 1 patient did not exceed 6 min. The total cost of the device was calculated to be <2,000 EUR. CONCLUSIONS In the face of very limited offer of commercially available pleural manometers, it is possible to successfully construct a self-made, reliable, electronic pleural manometer at modest costs. The device is easy to use and enables data display and storage in the personal computer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تخمین فشار متوسط شریانی توسط پایش تهاجمی فشار شریانی با مانومتر

Background: Direct monitoring of arterial pressure using a transducer system is not affordable in most operating rooms and ICU wards in Iran. It is, however, possible to use an aneroid manometer instead, but it is not standardized yet, nor studied enough and its measurements may not be interpretable. Methods: To study the correlation of the arterial pressure readings between a manometer and a ...

متن کامل

Pleural manometry: technique and clinical implications.

INTRODUCTION Pleural manometry during large-volume thoracentesis can prevent the development of excessively negative pleural pressures, which have been associated with re-expansion pulmonary edema; can diagnose an unexpandable lung; and can predict pleurodesis success. We currently perform pleural manometry simultaneously with both a vertical-column water manometer with an interposed resistive ...

متن کامل

Closed intrapleural pneumonolysis.

In 1882, Forlanini12 of Milan proposed the induction of artificial pneumothorax in patients suffering from pulmonary tuberculosis, and in 1894’s he published his experience with the first patients to be submitted to this form of therapy. In 1885 Cayley had reported the case of a tuberculous patient in whom he had induced pneuniothorax by open incision of the chest wall to control hemoptysis, an...

متن کامل

A wet/wet differential pressure sensor for measuring vertical hydraulic gradient.

Vertical hydraulic gradient is commonly measured in rivers, lakes, and streams for studies of groundwater-surface water interaction. While a number of methods with subtle differences have been applied, these methods can generally be separated into two categories; measuring surface water elevation and pressure in the subsurface separately or making direct measurements of the head difference with...

متن کامل

Accuracy of automated blood pressure monitors.

PURPOSE The purpose of this study is to determine if automated and aneroid manometers are as accurate a means of determining blood pressure as the mercury manometer. Obtaining vital signs for patients is considered standard of care, yet many dental offices do not routinely perform this health service because of technique inconsistencies and time constraints. The use of automatic blood pressure ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiration; international review of thoracic diseases

دوره 82 4  شماره 

صفحات  -

تاریخ انتشار 2011