Generalized optimal current patterns and electrical safety in EIT.
نویسندگان
چکیده
There are a number of constraints which limit the current and voltages which can be applied on a multiple drive electrical imaging system. One obvious constraint is to limit the maximum ohmic power dissipated in the body. Current patterns optimizing distinguishability with respect to this constraint are singular functions of the difference of transconductance matrices with respect to the power norm (the optimal currents of Isaacson). If one constrains the total current (L1 norm) the optimal patterns are pair drives. On the other hand if one constrains the maximum current on each drive electrode (an L(infinity) norm), the optimal patterns have each drive channel set to the maximum source or sink current value. In this paper we consider appropriate safety constraints and discuss how to find the optimal current patterns with those constraints.
منابع مشابه
Electrical Impedance Tomography (EIT) and Its Medical Applications: A Review
This paper reviews the principles of Electrical Impedance Tomography (EIT), different types of current patterns and reconstruction algorithms to assess its potential in medical imaging. A current injection pattern in EIT has its own current distribution profile within the subject under test. Hence, different current patterns have different sensitivity, spatial resolution and distinguishability....
متن کاملApplications of Electrical Impedance Tomography in Neurology
Introduction: Electrical impedance tomography (EIT) is a non-invasive technique utilized in various medical applications, including brain imaging and other neurological diseases. Recognizing the physiological and anatomical characteristics of organs based on their electrical properties is one of the main applications of EIT, as each variety of tissue structure has its own electrical characteris...
متن کاملFrequency-Division Multiplexing for Electrical Impedance Tomography in Biomedical Applications
Electrical impedance tomography (EIT) produces an image of the electrical impedance distribution of tissues in the body, using electrodes that are placed on the periphery of the imaged area. These electrodes inject currents and measure voltages and from these data, the impedance can be computed. Traditional EIT systems usually inject current patterns in a serial manner which means that the impe...
متن کاملAdjacent stimulation and measurement patterns considered harmful.
We characterize the ability of electrical impedance tomography (EIT) to distinguish changes in internal conductivity distributions, and analyze it as a function of stimulation and measurement patterns. A distinguishability measure, z, is proposed which is related to the signal-to-noise ratio of a medium and to the probability of detection of conductivity changes in a region of interest. z is a ...
متن کاملEIT Image Reconstruction by Modified Data
Electrical impedance tomography (EIT) is a radiation-free imaging method. Canonically, in lung EIT, 16 electrodes are placed horizontally on the thorax skin. By injecting currents through electrodes attached to the skin, a set of induced voltage measurements can be collected. The conductivity distribution on the chest plane can be obtained from these electrical boundary conditions. It has been ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physiological measurement
دوره 22 1 شماره
صفحات -
تاریخ انتشار 2001