Ultrasound evaluation of first trimester pregnancy complications.

نویسندگان

  • Lucie Morin
  • Michiel C Van den Hof
چکیده

OBJECTIVE To review the biological effects and safety of obstetric ultrasound. OUTCOME Outline the circumstances in which safety may be a concern with obstetric ultrasound. EVIDENCE Medline was searched, and a review of a document on this subject published by Health Canada and of bibliographies from identified articles was conducted. VALUES Review by principal authors and the Diagnostic Imaging Committee of the SOGC. The level of evidence was judged as outlined by the Canadian Task Force on the Periodic Health Examination. BENEFITS, HARMS AND COSTS Obstetric ultrasound should only be done for medical reasons, and exposure should be kept as low as reasonably achievable (ALARA) because of the potential for tissue heating. Higher energy is of particular concern for pulsed Doppler, colour flow, first trimester ultrasound with a long transvesical path (> 5 cm), second or third trimester exams when bone is in the focal zone, as well as when scanning tissue with minimal perfusion (embryonic) or in patients who are febrile. Operators can minimize risk by limiting dwell time, limiting exposure to critical structures, and following equipment generated exposure information. Recommendations 1. Obstetric ultrasound should only be used when the potential medical benefit outweighs any theoretical or potential risk (II-2A). 2. Obstetric ultrasound should not be used for nonmedical reasons, such as sex determination, producing nonmedical photos or videos, or for commercial purposes ( III-B). 3. Ultrasound exposure should be as low as reasonably achievable (ALARA) because of the potential for tissue heating when the thermal index exceeds 1. Exposure can be reduced through the use of output control and (or) by reducing the amount of time the beam is focused on one place (dwell time) (II-1A). 4. All diagnostic ultrasound devices should comply with the output display standards (MI and TI) (III-B). 5. When ultrasound is done for research or teaching purposes, exposed individuals should be informed if either the MI or TI are greater than 1 and how this exposure compares to that found in normal diagnostic practice (III-B). 6. While imaging the fetus in the first trimester, Doppler and colour Doppler should be avoided (III-B).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

I-40: Ultrasound in Multiple Pregnancy

Ultrasound has revolutioned the care of women carring twins. First trimester evaluation is the best time to determine chorioniocity and amnioniocity in multiple gestations. First trimester diagnosis is based on the number of gestational sacs, amnions and yolk sacs. Growth rate in multiple multiple gestations during the fist and early second trimesters parallels the growth rate of singleton preg...

متن کامل

Inm-1: Indication of First Trimester Sonongraphy

Improvement in ultrasound technology, including transvaginalsonography and higher frequency probes, has led to a better understanding of early pregnancy development. The first trimester ultrasound have been identified that can be used to reassure women that their pregnancy is progressing normally or abnormal them that their pregnancy will fail. The practicing radiologist and obstetrician must b...

متن کامل

O-37: Yolk Sac Diameter and Embryonic Heart Rate As Prognostic Factors of First Trimester Spontaneous Miscarriage

Background: During the past 20 years a lot of information is achieved about the first trimester of pregnancy through ultrasound and intrauterine fertilization. Many researchers tried to use the symptoms of ultrasound in early pregnancy like measuring the gestational sac and yolk sac of the pregnancy to predict the continuation of pregnancy. Aim of the recent study is to predict the risk of spon...

متن کامل

The use of interventional ultrasound in early pregnancy complications

Background: The use of ultrasound to establish pregnancy location, viability and gestational age in the first trimester is well established. In addition to the conventional uses of ultrasound in early pregnancy, interventional ultrasound may also be used to guide clinicians during surgical procedures for the management of early pregnancy complications (i.e. treatment of ectopic pregnancy, caesa...

متن کامل

Evaluation of the relationship between the back of the neck and the incidence of Turner syndrome in the first trimester of pregnancy

Abstract Background and Aim: Children with various anomalies are economically, emotionally charged for the family and society. The purpose of this study was to evaluate the value of Nuchal translucency (NT) in the diagnosis of Turner Syndrome in the first trimester of pregnancy. Materials and Methods: This prospective study was performed on 1522 pregnant women with gestational age of 11 to 13 w...

متن کامل

SOGC clinical practice guidelines: ultrasound evaluation of first trimester pregnancy complications.

OBJECTIVES First, to review normal embryonic development and the sonographic evidence of early pregnancy failure; second, to review sonographic evidence of ectopic pregnancy. OUTCOMES First, prediction of pregnancy failure, second, sonographic identification of ectopic pregnancy. EVIDENCE A MEDLINE search and review of bibliographies in identified articles was conducted. VALUES The eviden...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of obstetrics and gynaecology Canada : JOGC = Journal d'obstetrique et gynecologie du Canada : JOGC

دوره 27 6  شماره 

صفحات  -

تاریخ انتشار 2005