Blood screening using diffraction phase cytometry.

نویسندگان

  • Mustafa Mir
  • Huafeng Ding
  • Zhuo Wang
  • Jason Reedy
  • Krishnarao Tangella
  • Gabriel Popescu
چکیده

Blood smear analysis has remained a crucial diagnostic tool for pathologists despite the advent of automatic analyzers such as flow cytometers and impedance counters. Though these current methods have proven to be indispensible tools for physicians and researchers alike, they provide limited information on the detailed morphology of individual cells, and merely alert the operator to manually examine a blood smear by raising flags when abnormalities are detected. We demonstrate an automatic interferometry-based smear analysis technique known as diffraction phase cytometry (DPC), which is capable of providing the same information on red blood cells as is provided by current clinical analyzers, while rendering additional, currently unavailable parameters on the 2-D and 3-D morphology of individual red blood cells. To validate the utility of our technique in a clinical setting, we present a comparison between tests generated from 32 patients by a state of the art clinical impedance counter and DPC.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diffraction Phase Cytometry: blood on a CD-ROM.

We demonstrate Diffraction Phase Cytometry (DPC) as a single shot, full-field, high throughput quantitative phase imaging modality, dedicated to analyzing whole blood smears. Utilizing a commercial CD as a sample substrate, along with dynamic spatial filtering via a liquid crystal spatial light modulator, we have developed a compact instrument capable of making quantitative, physiologically rel...

متن کامل

Biocompatibility of magnetic Fe3O4 nanoparticles and their cytotoxic effect on MCF-7 cells

BACKGROUND The objective of this study was to evaluate the synthesis and biocompatibility of Fe₃O₄ nanoparticles and investigate their therapeutic effects when combined with magnetic fluid hyperthermia on cultured MCF-7 cancer cells. METHODS Magnetic Fe₃O₄ nanoparticles were prepared using a coprecipitation method. The appearance, structure, phase composition, functional groups, surface charg...

متن کامل

Platelet antibody screening by flow cytometry is more sensitive than solid phase red cell adherence assay and lymphocytotoxicity technique: a comparative study in Thai patients.

The objective of this study was to compare the sensitivity and specificity of lymphocytotoxicity test (LCT), solid phase red cell adherence assay (SPRCA) and flow cytometry in detecting platelet reactive antibodies against human leukocyte antigens (HLA) class I and human platelet antigens (HPA). Sera from 38 thrombocytopenic patients and 5 mothers of thrombocytopenic newborns were screened for ...

متن کامل

Screening for platelet antibodies in adult idiopathic thrombocytopenic purpura: a comparative study using solid phase red cell adherence assay and flow cytometry.

BACKGROUND Idiopathic thrombocytopenic purpura (ITP) is an autoimmune disorder caused by antiplatelet autoantibodies. In this study, we compared 2 methods for screening serum platelet antibodies in patients with ITP. METHODS A total of 44 adult patients were clinically classified with ITP. We used 2 indirect tests to detect human leukocyte antigen antibodies and/or platelet-specific antibodie...

متن کامل

Detection of significant bacteriuria by automated urinalysis using flow cytometry.

A new flow cytometry-based automated urine analyzer, the UF-50, was evaluated for its ability to screen urine samples for significant bacteriuria. One hundred eighty-six urine specimens from patients attending an outpatient clinic of a university-based hospital were examined. The results obtained with the UF-50 were compared with those obtained by conventional quantitative urine culture. The UF...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 15 2  شماره 

صفحات  -

تاریخ انتشار 2010