Intraocular Lens Power Calculation after Refractive Surgery: A Comparative Analysis of Accuracy and Predictability

نویسندگان

  • Byeong Soo Kang
  • Jeong Mo Han
  • Joo Youn Oh
  • Mee Kum Kim
  • Won Ryang Wee
چکیده

PURPOSE To compare the accuracy of intraocular lens (IOL) power calculation using conventional regression formulae or the American Society of Cataract and Refractive Surgery (ASCRS) IOL power calculator for previous corneal refractive surgery. METHODS We retrospectively reviewed 96 eyes from 68 patients that had undergone cataract surgery after keratorefractive surgeries. We calculated the formula with two approaches: IOL powers using the ASCRS IOL power calculator and IOL powers using conventional formulae with previous refractive data (Camellin, Jarade, Savini, and clinical history method) or without prior data (0, 2 and, 4 mm total mean power in topography, Wang-Koch-Maloney, Shammas, Seitz, and Maloney). Two conventional IOL formulae (the SRK/T and the Hoffer Q) were calculated with the single K and double K methods. Mean arithmetic refractive error and mean absolute error were calculated at the first postoperative month. RESULTS In conventional formulae, the Jarade method or the Seitz method, applied in the Hoffer Q formula with the single K or double K method, have the lowest prediction errors. The least prediction error was found in the Shammas-PL method in the ASCRS group. There was no statistically significant difference between the 10 lowest mean absolute error conventional methods, the Shammas-PL method and the Barrett True-K method calculated with using the ASCRS calculator, without using preoperative data. CONCLUSIONS The Shammas-PL formula and the Barrett True-K formula, calculated with the ASCRS calculator, without using history, were methods comparable to the 10 most accurate conventional formulae. Other methods using the ASCRS calculator show a myopic tendency.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraoperative biometry for intraocular lens (IOL) power calculation at silicone oil removal.

PURPOSE Cataract development is common following retinal detachment surgery that necessitates silicone oil injection. Intraocular lens (IOL) power calculation in the presence of silicone oil is challenging for many reasons. The authors evaluated the accuracy of intraoperative biometry during cataract surgery in silicone-filled eyes. METHODS Twelve cases of cataract in eyes filled with silicon...

متن کامل

Prediction error and accuracy of intraocular lens power calculation in pediatric patient comparing SRK II and Pediatric IOL Calculator

BACKGROUND Despite growing number of intraocular lens power calculation formulas, there is no evidence that these formulas have good predictive accuracy in pediatric, whose eyes are still undergoing rapid growth and refractive changes. This study is intended to compare the prediction error and the accuracy of predictability of intraocular lens power calculation in pediatric patients at 3 month ...

متن کامل

Visual and Refractive Results of Cataract Surgery by Phacoemulsification Method in Patients with Keratoconus

Purpose: To examine the visual and refractive results of cataract surgery by phacoemulsification method in patients with keratoconus. Methods: In this retrospective study, the files of patients with keratoconus, who underwent phacoemulsification between 2008 and 2017, were evaluated. The intraocular lens power calculation formula was SRK/T. Post-operative visual and refractive results were anal...

متن کامل

مقایسه‌ی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبه‌ی لنز داخل چشمی افراد با قرنیه‌ی طبیعی

Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...

متن کامل

Intraocular lens power calculatio n after corneal refractive surgery

Current Opinion in Ophthalmology 2008, 19:357–362 Purpose of review Corneal refractive procedures have become increasingly popular over the past decade allowing patients to have excellent uncorrected visual acuity and spectacle independence. As these individuals mature, many will eventually undergo cataract surgery. With the advances in modern cataract surgery and lens implant technology, parti...