A multifunctional micro-fluidic system for dielectrophoretic concentration coupled with immuno-capture of low numbers of Listeria monocytogenes.

نویسندگان

  • Liju Yang
  • Padmapriya P Banada
  • Mohammad R Chatni
  • Kwan Seop Lim
  • Arun K Bhunia
  • Michael Ladisch
  • Rashid Bashir
چکیده

In this study, we demonstrated a micro-fluidic system with multiple functions, including concentration of bacteria using dielectrophoresis (DEP) and selective capture using antibody recognition, resulting in a high capture efficiency of bacterial cells. The device consisted of an array of oxide covered interdigitated electrodes on a flat silicon substrate and a approximately 16 microm high and approximately 260 microm wide micro-channel within a PDMS cover. For selective capture of Listeria monocytogenes from the samples, the channel surface was functionalized with a biotinylated BSA-streptavidin-biotinylated monoclonal antibody sandwich structure. Positive DEP (at 20 V(pp) and 1 MHz) was used to concentrate bacterial cells from the fluid flow. DEP could collect approximately 90% of the cells in a continuous flow at a flow rate of 0.2 microl min(-1) into the micro-channel with concentration factors between 10(2)-10(3), in sample volumes of 5-20 microl. A high flow rate of 0.6 microl min(-1) reduced the DEP capture efficiency to approximately 65%. Positive DEP attracts cells to the edges of the electrodes where the field gradient is the highest. Cells concentrated by DEP were captured by the antibodies immobilized on the channel surface with efficiencies of 18 to 27% with bacterial cell numbers ranging from 10(1) to 10(3) cells. It was found that DEP operation in our experiments did not cause any irreversible damage to bacterial cells in terms of cell viability. In addition, increased antigen expression (antigens to C11E9 monoclonal antibody) on cell membranes was observed following the exposure to DEP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

US . Patent Jun . 16 ,

Christie, in Advances in Lipid Methodology-Two, pp. 195-213, Ed. Christie, Oily Press, 1993* Earlix et al., Dis. Aquat. Org., 27:19-24, 1996* Pettipher et al. (Appl. Environ. Microbiol., 44:809-813, 1982).* Bwatwa et al. (Abstract ANYL-349, Book of Abstracts, 229th ACS National Meeting, Mar. 13, 2005).* Besse et al. (Food Microbiol., 18:669-676, 2001).* Cloak et al. (J. Appl. Microbiol., 86:583...

متن کامل

Foodborne Listeriosis

Foodborne listeriosis is a rare and very dangerous disease which is caused by Listeria monocytogenes. This bacterium is found in the nature in very high population, but can cause disease only in certain groups of people. Listeriosis usually happens after consumption of unpasteurized dairy products especially soft and unripe cheeses and ready to eat meat products like hot dog by susceptible peop...

متن کامل

Design and Simulation of a Fluidic Micro-Bio-Sensor Based on Resonator Array

In this paper, a fluidic biosensor with possibility to fabricate by Micro-Electro-Mechanical Systems (MEMS) technology is proposed for biomedical mass detection and lab-on-chip applications. This is designed by electromechanical coupling of harmonic micromechanical resonators with harmonic springers as a mechanical resonator array. It can disperse mechanical wave along the array by electrostati...

متن کامل

Polymer-based microfluidic chip for rapid and efficient immunomagnetic capture and release of Listeria monocytogenes.

Infections caused by foodborne pathogens such as Listeria monocytogenes pose a threat to public health while timely detection is challenging due to pathogen low numbers. The development of robust and efficient sample preparation techniques is crucial to improve detection sensitivity and workflow. Immunomagnetic separation using magnetic nanoparticles (MNPs) is attractive, as it can efficiently ...

متن کامل

Effects of Dielectrophoresis on Growth, Viability and Immuno-reactivity of Listeria monocytogenes

Dielectrophoresis (DEP) has been regarded as a useful tool for manipulating biological cells prior to the detection of cells. Since DEP uses high AC electrical fields, it is important to examine whether these electrical fields in any way damage cells or affect their characteristics in subsequent analytical procedures. In this study, we investigated the effects of DEP manipulation on the charact...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lab on a chip

دوره 6 7  شماره 

صفحات  -

تاریخ انتشار 2006