Complications associated with the ball, bar and Locator attachments for implant-supported overdentures.

نویسندگان

  • Sirmahan Cakarer
  • Taylan Can
  • Mehmet Yaltirik
  • Cengizhan Keskin
چکیده

BACKGROUND The purpose of this clinical study was to evaluate the complications associated with the different attachments used in implant-supported overdentures, including prosthetic problems and implant failures. A comparison of ball, bar and Locator (Zest Anchors, Inc, homepage, Escondido, CA, USA) attachments, in completely edentulous patients with two, three or four implants, was conducted. MATERIAL AND METHODS A total of 36 edentulous patients (20 female, 16 male) with a mean age of 66.3 years, were enrolled in the study. The patients were treated with 95 implants, for the prosthetic restoration of the maxilla or the mandible. The mean follow-up time was 41.17 months. Prosthetic complications including, fractured overdentures, replacements of O-ring attachment and retention clips, implant failures, hygiene problems, mucosal enlargements, attachment fractures, retention loss and dislodgement of the attachments were recorded and evaluated. The recall visits at 3, 6, 12 months and, annually thereafter. RESULTS Fourteen complications in the ballattachment group and 7 complications in the bar group were observed. No complications were observed in the locator group. The difference was found to be as statistically significant (p=0,009). Six of the 95 implants had failed. Totally 39 implant overdentures were applied. Three prostheses were renewed because of fractures. CONCLUSION Within the limits of the present study, it was concluded that the locator system showed superior clinical results than the ball and the bar attachments, with regard to the rate of prosthodontic complications and the maintenance of the oral function.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity

Comparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity Dr. A. Saboori* - Dr. Gh. Esfahanizade** - Dr. M. Ejlali*** *- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Shaheed Beheshti University of Medical Sciences. **- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Tehran Isl...

متن کامل

Comparison of the Effect of Ball and Bar Attachment Designs on Retention and Stability of Mandibular Implant-Supported Overdentures

Objectives: The present study evaluated the effect of bar and ball attachment designs on retention and stability of a mandibular overdenture supported by four implants. Methods: An edentulous mandibular acrylic resin model with four implants in the anterior part of the ridge (A, B, D and E) was fabricated. A metal framework simulating the overdenture was also fabricated. Totally, 30...

متن کامل

A clinical comparison of prosthetic complications of implant-supported overdentures with different attachment systems.

OBJECTIVES The objective of this clinical study was to evaluate the prosthetic complications of patients with 2 to 4 implants splinted with a round bar or with 2 to 4 unsplinted implants with ball attachments during the follow-up period. METHODS A total of 26 patients were included in this study. Patients were randomly provided with a round bar or with ball attachments that were used to retai...

متن کامل

The Amount of Wear in Attachment of Implant-Supported Overdentures in Mandible

Background and objectives: One of the simplest and cheapest attachments for overdentures, is the ball-type attachment, however, keeping it during the first year of prosthesis delivery and after that is one of the main concerns of dentists. The present study aimed to assess the wear of matrix in overdentures attachment supported by one, two and three implants in the mandible. Materials and metho...

متن کامل

Effect of attachment type on load distribution to implant abutments and the residual ridge in mandibular implant-supported overdentures

This study aimed to investigate the effect of attachment type on the load transmitted to implants and the residual ridge in a mandibular two-implant-supported overdenture in a model study. Ball attachments, locator attachments, and round-bar attachments were selected and examined. Static and dynamic vertical loads of 100 N were applied in the right first molar region. The load on the implants w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medicina oral, patologia oral y cirugia bucal

دوره 16 7  شماره 

صفحات  -