Transcatheter aortic valve implantation in failed bioprosthetic surgical valves.

نویسندگان

  • Danny Dvir
  • John G Webb
  • Sabine Bleiziffer
  • Miralem Pasic
  • Ron Waksman
  • Susheel Kodali
  • Marco Barbanti
  • Azeem Latib
  • Ulrich Schaefer
  • Josep Rodés-Cabau
  • Hendrik Treede
  • Nicolo Piazza
  • David Hildick-Smith
  • Dominique Himbert
  • Thomas Walther
  • Christian Hengstenberg
  • Henrik Nissen
  • Raffi Bekeredjian
  • Patrizia Presbitero
  • Enrico Ferrari
  • Amit Segev
  • Arend de Weger
  • Stephan Windecker
  • Neil E Moat
  • Massimo Napodano
  • Manuel Wilbring
  • Alfredo G Cerillo
  • Stephen Brecker
  • Didier Tchetche
  • Thierry Lefèvre
  • Federico De Marco
  • Claudia Fiorina
  • Anna Sonia Petronio
  • Rui C Teles
  • Luca Testa
  • Jean-Claude Laborde
  • Martin B Leon
  • Ran Kornowski
چکیده

IMPORTANCE Owing to a considerable shift toward bioprosthesis implantation rather than mechanical valves, it is expected that patients will increasingly present with degenerated bioprostheses in the next few years. Transcatheter aortic valve-in-valve implantation is a less invasive approach for patients with structural valve deterioration; however, a comprehensive evaluation of survival after the procedure has not yet been performed. OBJECTIVE To determine the survival of patients after transcatheter valve-in-valve implantation inside failed surgical bioprosthetic valves. DESIGN, SETTING, AND PARTICIPANTS Correlates for survival were evaluated using a multinational valve-in-valve registry that included 459 patients with degenerated bioprosthetic valves undergoing valve-in-valve implantation between 2007 and May 2013 in 55 centers (mean age, 77.6 [SD, 9.8] years; 56% men; median Society of Thoracic Surgeons mortality prediction score, 9.8% [interquartile range, 7.7%-16%]). Surgical valves were classified as small (≤21 mm; 29.7%), intermediate (>21 and <25 mm; 39.3%), and large (≥25 mm; 31%). Implanted devices included both balloon- and self-expandable valves. MAIN OUTCOMES AND MEASURES Survival, stroke, and New York Heart Association functional class. RESULTS Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83.2% (95% CI, 80.8%-84.7%; 62 death events; 228 survivors). Patients in the stenosis group had worse 1-year survival (76.6%; 95% CI, 68.9%-83.1%; 34 deaths; 86 survivors) in comparison with the regurgitation group (91.2%; 95% CI, 85.7%-96.7%; 10 deaths; 76 survivors) and the combined group (83.9%; 95% CI, 76.8%-91%; 18 deaths; 66 survivors) (P = .01). Similarly, patients with small valves had worse 1-year survival (74.8% [95% CI, 66.2%-83.4%]; 27 deaths; 57 survivors) vs with intermediate-sized valves (81.8%; 95% CI, 75.3%-88.3%; 26 deaths; 92 survivors) and with large valves (93.3%; 95% CI, 85.7%-96.7%; 7 deaths; 73 survivors) (P = .001). Factors associated with mortality within 1 year included having small surgical bioprosthesis (≤21 mm; hazard ratio, 2.04; 95% CI, 1.14-3.67; P = .02) and baseline stenosis (vs regurgitation; hazard ratio, 3.07; 95% CI, 1.33-7.08; P = .008). CONCLUSIONS AND RELEVANCE In this registry of patients who underwent transcatheter valve-in-valve implantation for degenerated bioprosthetic aortic valves, overall 1-year survival was 83.2%. Survival was lower among patients with small bioprostheses and those with predominant surgical valve stenosis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcatheter aortic valve-in-valve implantation for patients with degenerative surgical bioprosthetic valves.

Most surgical heart valves currently implanted are bioprosthetic tissue valves. Such valves deteriorate with time, eventually presenting with either stenosis or regurgitation. Reoperation, the current standard of care for failed valves, carries significant risk in terms of both morbidity and mortality. Implantation of a transcatheter valve inside a failed surgical valve (valve-in-valve procedur...

متن کامل

Transcatheter valve-in-valve implantation for failed surgical bioprosthetic valves.

When bioprosthetic cardiac valves fail, reoperative valve replacement carries a higher risk of morbidity and mortality compared with initial valve replacement. Transcatheter heart valve implantation may be a viable alternative to surgical aortic valve replacement for high-risk patients with native aortic stenosis, and valve-in-valve (V-in-V) implantation has been successfully performed for fail...

متن کامل

Severe Aortic Regurgitation in Degenerative Bioprosthetic Aortic Homograft Treated by Valve in Valve

Bioprosthetic valves are increasingly used in patients with aortic valve stenosis. In comparison with mechanical valves, these valves have a lower risk of thromboembolism and no need for anticoagulation [1,2]. However, the durability is limited; the best current valves are expected to degenerate in 10 to 20 years, resulting in stenosis or regurgitation or combined pathology. Surgical aortic val...

متن کامل

Transcatheter Aortic and Mitral Valve-in-Valve Implantation for Failed Surgical Bioprosthetic Valves: An 8-Year Single-Center Experience.

OBJECTIVES We report our 8-year experience in transcatheter aortic and mitral valve-in-valve (VinV) implantation. BACKGROUND Feasibility and good early outcomes associated with transcatheter aortic and mitral VinV implantation into failed surgical bioprostheses have been confirmed, but the mid-term and long-term outcomes of transcatheter aortic and mitral VinV is unknown. METHODS A total of...

متن کامل

Transcatheter Aortic Valve Replacement: A Review Article

Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • JAMA

دوره 312 2  شماره 

صفحات  -

تاریخ انتشار 2014