The Formetric 4D System (Diers International GmbH, Schlangenbad, Germany) is a surface topography system used to evaluate trunk deformity in patients with scoliosis. The original system took a single static scan of the patient which was subject to variability due to the natural sway of the body during standing. A 4D system was developed that takes multiple scans over 6 seconds and averages them to take into account patient movement during imaging. Averaged scans such as this should show less variability over time than single images do [1-4]. The purpose of this study was to compare surface topography measurements taken as a single scan with those taken as averaged scans over 6 and 15 seconds to see whether the averaged scans have less variability. Six volunteer patients without scoliosis were used to measure the position of normal spines in the standing position. Each patient was scanned ten times for each time interval. For each group of scans, a standard error of measurement was calculated. The patients were then compared based on the standard errors for each topography parameter. Data included 6 patients x30 measurements each x10 topography parameters totaling 1800 data points. Data analysis was done using ANOVA to compare the three groups. There were not significant differences between the groups in any of the surface topography parameters that were studied. Our conclusion was that in this population of 6 normal patients, we were not able to demonstrate smaller standard errors of measurement with averaged 4D scans than with single scans. Author details Rosalind Franklin University North Chicago, USA. Illinois Bone and Joint Institute, USA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation of lateral deviation and rotation of the spine in static and dynamic surface topography

Background The use of SST (Spine and Surface Topography) can significantly reduce the amount of harmful radiation in scoliosis treatment and follow-up. So far the SST examination procedure was only possible in a standing/ upright position of the patient. Newer developments also allow dynamic measurements of the spine in motion. Dynamic SST is a step forward in functional analysis of the spine.

متن کامل

A comparison of authomatic vs. manual detection of anatomical landmarks during surface topography evaluation using the formtric 4D system

Background The Formetric 4D System (Diers International GmbH, Schlangenbad Germany) is a popular system for measuring surface topography in patients with adolescent scoliosis [1-4]. The system automatically detects anatomic landmarks on the patient, but then gives the user the opportunity to make adjustments to those landmarks if necessary. The purpose of this study was to see whether there wou...

متن کامل

Development of an apparatus to evaluate Adolescent Idiopathic Scoliosis by dynamic surface topography.

For cases of Adolescent Idiopathic Scoliosis (AIS), commonly the first indicator is a change in the surface shape of the back over time. A proportion of patients so diagnosed require surgical intervention to prevent further progression and to improve cosmesis. The results of a preliminary literature survey have revealed that significant work has already been published on the static acquisition ...

متن کامل

Effect of Soft Knee Support on Dynamic and Static Balance in the Male Elderly

Objectives: Joint supporters can caused increasing proprioceptive information. Such proprioceptive information is needed for balance. The purpose of this study was to determine the effect of soft knee support on static and dynamic balance tests in male elderly (65 years and older). Methods & Materials: Via a randomized clinical trial study design, 22 elderly were selected and divided into tw...

متن کامل

Comparison of Radiographic and Surface Topography Measurements in Adolescents with Idiopathic Scoliosis

PURPOSE In patients with adolescent idiopathic scoliosis (AIS), radiographic surveillance is the gold standard of assessing spinal deformity, but has negative long-term effects. The Formetric 4D surface topography system was compared to standard radiography as a safer option for evaluating patients with AIS. METHODS Fourteen volunteers with typical AIS patient stature had 30 repeated Formetri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012