Patch Testing with the Swedish Baseline Series in Two Countries

ثبت نشده
چکیده

Patch testing is a very effective mean to investigate causes of allergic contact dermatitis (ACD), but results obtained in different countries is usually hard to compare due to reading of patch tests. The aim of the study was to examine the prevalence of contact allergy to substances present in the Swedish baseline series and to compare results between the clinics in Vilnius and Sweden when the patch test procedure is similar in both countries. Consecutive patients with suspected ACD were tested with the Swedish baseline series at the university hospitals in Malmö, Sweden, and Vilnius, Lithuania in the years 2010–2012. Positive patch test reactions to at least one allergen was observed in 115 (53.7%) in Lithuania and in 237 (55.4%) in Sweden. The top 5 most frequent allergens (and respective prevalence rates) in Lithuania were as follows: nickel sulphate (25.7%), methylchloroisothiazolinone/methylisothiazolinone (MCI/MI) (10.3%), cobalt chloride (7.5%), potassium dichromate (6.1%), formaldehyde (6.1%). The most prevalent positive patch tests reactions in Sweden were to nickel sulphate (18.9%), cobalt chloride (6.3%), M. pereirae resin (5.6%), MCI/MI (4.9%), Amerchol L 101 (4%). Statistically relevant differences were seen in sensitization to preservatives (3.7% in Lithuania and 1.8% in Sweden, p<0.001) and metals (13.1% in Lithuania and 9.3% in Sweden, p<0.03). In conclusion, this multicenter study provides some information on the prevalence of contact allergy to the most common contact allergens in two countries, although it is not possible to establish if the different prevalence was due to the difference in atopic background or allergen exposure. This should be further investigated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Patch testing with a textile dye mix in a baseline series in two countries.

Disperse dyes are the most common contact sensitizers among textile dyes. The main aim of this study was to investigate the outcome of patch testing with a textile dye mix 6.6%. A total of 2,049 patients from Sweden and 497 from Belgium were tested with the mix, consisting of Disperse (D) Blue 35, D Yellow 3, D Orange 1 and 3, D Red 1 and 17, 1.0% each, and D Blue 106 and D Blue 124, 0.3% each....

متن کامل

Multicentre patch testing with compositae mix by the Swedish Contact Dermatitis Research Group.

Sesquiterpene lactone mix detects contact allergy to these compounds present in the plant family Asteraceae. This marker is present in many baseline series. An additional marker is Compositae mix, which is not present in many baseline series. To investigate whether this allergen should be inserted into the Swedish baseline series, six dermatology centres representing the Swedish Contact Dermati...

متن کامل

Swedish Experiences From Patch Testing Methylisothiazolinone Separately.

The preservative methylchloroisothiazolinone/methylisothiazolinone (MCI/MI) is a well-known sensitiser and present in the Swedish baseline series since the 1980s. The proportions of MCI/MI are 3:1. MI alone has been used as a preservative since less than 10 years. This study was conducted on behalf of the Swedish Contact Dermatitis Research Group to evaluate inclusion of MI in the Swedish basel...

متن کامل

Patch testing with a textile dye mix in two concentrations - a multicentre study by the Swedish contact dermatitis research group.

UNLABELLED Disperse dyes, which are used for colouring synthetic textile fibres, are well-known contact sensitisers. To investigate the outcome of patch-testing with a textile dye mix (TDM) at 7 dermatology clinics in Sweden, a TDM tested at 2 concentrations was included into the baseline series during one year. The mix consisted of Disperse (D) Blue 35, D Yellow 3, D Orange 1 and 3, D Red 1 an...

متن کامل

Patch testing with formaldehyde 2.0% in parallel with 1.0% by the Swedish contact dermatitis research group.

In a multicentre study consecutively patch-tested dermatitis patients were tested simultaneously with 1.0% and 2.0% (w/v) formaldehyde in aqua applied with a micropipette (15 µl) to the filter paper disc in Finn Chambers (0.30 mg/cm(2) and 0.60 mg/cm(2), respectively). A total of 2,122 dermatitis patients were patch-tested. In all, 77 (3.6%) patients reacted positively to formaldehyde; 37 react...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015