Simplified spectrophotometric assay for microsomal 3-hydroxy-3-methylglutaryl CoA reductase by measurement of coenzyme A.

نویسندگان

  • F H Hulcher
  • W H Oleson
چکیده

A new assay for 3-hydroxy-3-methylglutaryl CoA reductase (mevalonate:NADP oxidoreductase [acylating CoA], EC 1.1.1.34) is based upon the measurement of released coenzyme A (SH) during the reduction of 3-hydroxy-3-methylglutaryl CoA to mevalonate. Coenzyme A was measured in the presence of dithiothreitol, required for activity, by reaction with 5,5'-dithiobis(2-nitrobenzoic acid). Sodium arsenite forms a complex with the dithiol, but not with monothiols. Thus, reduced coenzyme A reacts instantaneously with the reagent and dithiothreitol reacts slowly. The absorbance due to the coenzyme A-5,5'-dithiobis(2-nitrobenzoic acid) reaction is determined by extrapolating the linear (dithiol) absorbance-time curve to the time of addition of the reagent. After subtraction of control absorbance (deletion of NADPH), the concentration of CoA-SH is calculated from epsilon(max) = 1.36 x 10(4) at 412 nm. The method of protein removal and reduction of sulfhydryl groups on the enzyme are critical. This method provides an immediate assay. Recovery of reduced coenzyme A was 98.7%. The assay is applicable for microsomes or purified enzyme and has an effective range of 0.5-50 nmoles of coenzyme A. It was applied to kinetic measurement of the pigeon liver microsomal enzyme reaction. The apparent K(m) value for 3-hydroxy-3-methylglutaryl CoA was 1.75 x 10(-5) M, and for NADPH the value was 6.81 x 10(-4) M. This method was compared with the dual-label method at high and low levels of activity. The data were not statistically different.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simplified spectrophotometric assay

A new assay for 3-hydroxy-3-methylglutaryl CoA reductase (mevalonate: NADP oxidoreductase [acylating CoA] , EC 1.1.1.34) is based upon the measurement of released coenzyme A (SH) during the reduction of 3-hydroxy-3-methylglutaryl CoA to mevalonate. Coenzyme A was measured in the presence of dithiothreitol, required for activity, by reaction with 5,5’-dithiobis(2-nitrobenzoic acid). Sodium arsen...

متن کامل

Improved methods for the solubilization and assay of hepatic 3-hydroxy-3-methylglutaryl coenzyme A reductase.

A method for solubilizing HMG-CoA reductase is described that reproducibly yielded approximately 190% of the activity assayed in rat liver microsomes. Optimal solubilization occurred when microsomal membranes were frozen at a fixed concentration, thawed, homogenized in a buffer containing 50% glycerol, and incubated at 37 degrees C for 60 minutes. A rapid spectrophotometric assay of the reducta...

متن کامل

Optimization, Validation and Application of Spectrophotometric Assay for 3-Hydroxy-3-methylglutaryl- coenzyme A Reductase Activity

Purpose: To improve the sensitivity and specificity of spectrophotometric 3-hydroxy-3-methylglutarylcoenzyme A (HMG-CoA) reductase activity assay. Methods: Spectrophotometric HMG-CoA reductase detection in male Wistar rat liver microsomes was optimized by applying different conditions, such as reaction buffer pH, NADPH and protein concentration, and preincubation and reaction times. The optimal...

متن کامل

Improved methods for the assay and activation of 3-hydroxy-3-methylglutaryl coenzyme A reductase.

A simple and rapid mixed-phase method for the quantitative assay of 3-hydroxy-3-methylglutaryl (HMG)-CoA reductase and a procedure for the efficient reactivation of Mg-ATP-inactivated microsomal HMG-CoA reductase by potato acid phosphatase are described. The mixed-phase assay entails the direct addition of the acidified, deproteinized incubation mixture to a toluene-based scintillation fluor. T...

متن کامل

Determination of hepatic 3-hydroxy-3-methylglutaryl CoA reductase activity in man.

Procedures were developed for the determination of the activity of the microsomal enzyme 3-hydroxy-3-methylglutaryl CoA reductase (HMG CoA reductase, EC 1.1.1.34) in human liver. The enzyme assay could be carried out with as little as 20 mg of fresh liver tissue, thus making the method applicable to specimens obtained by percutaneous liver biopsy. Experiments were carried out to determine optim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of lipid research

دوره 14 6  شماره 

صفحات  -

تاریخ انتشار 1973