Practical approach for pretreatment verification of IMRT with flattening filter‐free (FFF) beams using Varian portal dosimetry
نویسندگان
چکیده
Patient-specific pretreatment verification of intensity-modulated radiation therapy (IMRT) or volumetric-modulated arc therapy (VMAT) is strongly recommended for all patients in order to detect any potential errors in treatment planning process and machine deliverability, and is thus performed routinely in many clinics. Portal dosimetry is an effective method for this purpose because of its prompt setup, easy data acquisition, and high spatial resolution. However, portal dosimetry cannot be applied to IMRT or VMAT with flattening filter-free (FFF) beams because of the high dose-rate saturation effect of the electronic portal imaging device (EPID). In our current report, we suggest a practical QA method of expanding the conventional portal dosimetry to FFF beams with a QA plan generated by the following three steps: 1) replace the FFF beams with flattening filtered (FF) beams of the same nominal energy; 2) reduce the dose rate to avoid the saturation effect of the EPID detector; and 3) adjust the total MU to match the gantry and MLC leaf motions. Two RapidArc plans with 6 and 10 MV FFF beams were selected, and QA plans were created by the aforementioned steps and delivered. The trajectory log files of TrueBeam obtained during the treatment and during the delivery of QA plan were analyzed and compared. The maximum discrepancies in the expected trajectories between the treatment and QA plans were within 0.002 MU for the MU, 0.06° for the motion of gantry rotation, and 0.006 mm for the positions of the MLC leaves, indicating much higher levels of accuracy compared to the mechanical specifications of the machine. For further validation of the method, direct comparisons of the delivered QA FF beam to the treatment FFF beam were performed using film dosimetry and show that gamma passing rates under 2%/2 mm criteria are 99.0%-100% for the all four arc beams. This method can be used on RapidArc plans with FFF beams without any additional procedure or modifications on the conventional portal dosimetry of IMRT and is, therefore, a practical option for routine clinical use. PACS numbers: 87.53.Kn, 87.55.T-, 87.56.bd, 87.59.-e.
منابع مشابه
EPID‐based dosimetry to verify IMRT planar dose distribution for the aS1200 EPID and FFF beams
We proposed to perform a basic dosimetry commissioning on a new imager sys-tem, the Varian aS1200 electronic portal imaging device (EPID) and TrueBeam 2.0 linear accelerator for flattened (FF) and flattening filter-free (FFF) beams, then to develop an image-based quality assurance (QA) model for verification of the system delivery accuracy for intensity-modulated radiation therapy (IMRT) treat-...
متن کاملFeasibility of portal dosimetry for flattening filter‐free radiotherapy
The feasibility of using portal dosimetry (PD) to verify 6 MV flattening filter-free (FFF) IMRT treatments was investigated. An Elekta Synergy linear accelerator with an Agility collimator capable of delivering FFF beams and a standard iViewGT amorphous silicon (aSi) EPID panel (RID 1640 AL5P) at a fixed SSD of 160 cm were used. Dose rates for FFF beams are up to four times higher than for conv...
متن کاملOn flattening filter‐free portal dosimetry
Varian introduced (in 2010) the option of removing the flattening filter (FF) in their C-Arm linacs for intensity-modulated treatments. This mode, called flattening filter-free (FFF), offers the advantage of a greater dose rate. Varian's "Portal Dosimetry" is an electronic portal imager device (EPID)-based tool for IMRT verification. This tool lacks the capability of verifying flattening filter...
متن کاملDosimetric Comparison between 6MV Flattened Filter and Flattening Filter Free Photon Beams in the Treatment of Glioblastoma with IMRT Technique: A Treatment Planning Study
Introduction: The present study evaluated the dosimetric comparison between 6MV flattened filter (FF) and flattening filter-free (FFF) photon beams in intensity-modulated radiation therapy (IMRT) technique for the treatment of glioblastoma (GBM) patients. Material and Methods: The present study was conducted on 10 patients with GBM previously...
متن کاملDosimetric Validation of Volumetric Modulated Arc Therapy (VMAT) Using AAPM TG-119 Benchmark Plans in an Upgraded CLINAC 2100CD for Flattening Filter Free (FFF) Photon Beams
Background: Recently we have upgraded our Varian Clinac 2100CD with a 6MV FFF beam, this upgrade being the first of its kind in our country. Even though the dosimetric characteristics of FFF beams have been reported both in experimental and Monte Carlo studies, application in planning and delivery is complex. The aim of this study was to validate the commissioning of upgraded FFF beams dosimetr...
متن کامل