Modeling of a Flooding Induced Station Blackout for a Pressurized Water Reactor Using the RISMC Toolkit
نویسندگان
چکیده
In the Risk-Informed Safety Margin Characterization (RISMC) approach we want to understand not just the frequency of an event like core damage, but how close we are (or are not) to key safety-related events and how might we increase our safety margins. The RISMC Pathway uses the probabilistic margin approach to quantify impacts to reliability and safety by coupling both probabilistic (via stochastic simulation) and mechanistic (via physics models) approaches. This coupling takes place through the interchange of physical parameters and operational or accident scenarios. In this paper we apply the RISMC approach to evaluate the impact of a power uprate on a pressurized water reactor (PWR) for a tsunami-induced flooding test case. This analysis is performed using the RISMC toolkit: RELAP-7 and RAVEN codes. RELAP-7 is the new generation of system analysis codes that is responsible for simulating the thermal-hydraulic dynamics of PWR and boiling water reactor systems. RAVEN has two capabilities: to act as a controller of the RELAP-7 simulation (e.g., system activation) and to perform statistical analyses (e.g., run multiple RELAP-7 simulations where sequencing/timing of events have been changed according to a set of stochastic distributions). By using the RISMC toolkit, we can evaluate how power uprate affects the system recovery measures needed to avoid core damage after the PWR lost all available AC power by a tsunami induced flooding. The simulation of the actual flooding is performed by using a smooth particle hydrodynamics code called NEUTRINO.
منابع مشابه
Analyzing Simulation-Based PRA Data Through Clustering: a BWR Station Blackout Case Study
Dynamic probabilistic risk assessment (DPRA) methodologies couple system simulator codes (e.g., RELAP, MELCOR) with simulation controller codes (e.g., RAVEN, ADAPT). Whereas system simulator codes accurately model system dynamics deterministically, simulation controller codes introduce both deterministic (e.g., system control logic, operating procedures) and stochastic (e.g., component failures...
متن کاملThermal-Hydraulics analysis of pressurized water reactor core by using single heated channel model
Thermal hydraulics of nuclear reactor as a basis of reactor safety has a very important role in reactor design and control. The thermal-hydraulic analysis provides input data to the reactor-physics analysis, whereas the latter gives information about the distribution of heat sources, which is needed to perform the thermal-hydraulic analysis. In this study single heated channel model as a very f...
متن کاملAnalyzing simulation-based PRA data through traditional and topological clustering: A BWR station blackout case study
Dynamic probabilistic risk assessment (DPRA) methodologies couple system simulator codes (e.g., RELAP, MELCOR) with simulation controller codes (e.g., RAVEN, ADAPT). Whereas system simulator codes model system dynamics deterministically, simulation controller codes introduce both deterministic (e.g., system control logic, operating procedures) and stochastic (e.g., component failures, parameter...
متن کاملCore Loading Design for Bushehr Pressurized Water Reactor
The modified out-in fuel management strategy was applied to the core loading design for the first four cycles of the Bushehr (Iran-1) KWU designed Pressurized Water Reactor (PWR). The minimum peak-to-average power density was chosen as the objective function of the optimization process. Lattice homogenization and group constants generation were performed by using the LEOPARD computer code. For ...
متن کاملAssessment of energy efficiency in pump stations of pressurized irrigation systems (case study: Qazvin and Kermanshah provinces)
About 20% of the electricity produced in the world is consumed in rotary equipment for conveying fluids such as water, gas, air, and other liquids, while the loss of energy consumption in this sector is more than 60%. The aim of this study is to evaluate different efficiencies in the pumping stations in the pressurized irrigation systems to address low energy efficiency issues in the pump stati...
متن کامل