P 241 Comparative study of one implantation of hema and PMMA iols in the rabbit

نویسندگان

  • C. Baudouin
  • M. Ettaiche
  • P. Gastaud
چکیده

m Implantation of posterior ch.unber lenses (intmcalar lens = IOL) is an established method to replace opaque lenses. Prefered positioning of implanted lenses is in the capsular bag. either with or without touching the posterior capsule. Purpose of the present study is to determine the real position of the implanted lens in relation to the posterior capsule and to measure a possible distance between IOL and posterior capsule by Scheimpflug-photography. Method: 62 eyes of 50 patients with uncomplicated senile cataract underwent pbacoemulsification and implantation of a posterior chamber lens during a period of 6 months. Postoperatively the position of the IOL was measured by Scheimpflug-photography. &&& Out of 62 pseudophacic eyes of 50 patients 48 photos were reproducible. 33 photos showed a measurable distance between posterior IOL and posterior capsule. In 15 photos the posterior IOL touched the posterior capsule. Conclusion: Against general assompt~on that the IOL normally touches the posterior capsule our results show that only about 30% of implanted posterior chamber lenses touch the posterior capsule. P240 A new coating method to improve intraocular lenses tolerance Puroose. Several attempts to trnprove the intraocular lenses tolerance by surface modification had been tried A new method of crosslinked heparin grafting is presented. Methods. A modified heparin 1s crosslinked on a pretreated PMMA surface. Heparin grafted clnto the surface is equivalent to a free short length chain An analysis of the surface has been carrred out by ESCA (electron spectroscopy for chemical analysrs). ReSultS The thrckness of the treat'nent was about 3 to 5 nm. The treated lenses were found biocompatible The coating was found mechamcally stable but also resistant to pH variation and to washing As antr-thrombogenic sites were used to graft the heparrn, the coating should not exhibit any ant+-thrombogenic effect In vitro experiments demonstrated that short length heparin chatns rnhrbrt fibroblasts growth factor activitya. Undergoing exoenments and clinical trials wc?re desraned to confirm these hypotheses. Results of these tests. will be presented. Conclusions: A new method has been developped to crosslinked heparin on lenses. Other properties than anti-inflammatory ones are expected from this new technique of heparin grafting. Experiments are underway to dernontrate them. Purpose: To investigate ocular biocompatibility of a new HEMA (hydroxyethylmetacrylate) foldable IOL. Material and methods: 16 albino rabbits underwent extracapsular lens extraction in the right eye, under general anesthesia, and were followed for one year: 6 rabbits were implanted with a 6mm HEMA IOL …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adhesion of lens capsule to intraocular lenses of polymethylmethacrylate, silicone, and acrylic foldable materials: an experimental study.

AIMS To investigate the adhesion characteristics of several intraocular lenses (IOLs) to the simulated and rabbit lens capsule. METHODS Adhesive force to bovine collagen sheets was measured in water with polymethylmethacrylate (PMMA), three piece silicone, and acrylic foldable IOLs. In rabbit eyes, phacoemulsification and IOL implantation were performed. Three weeks later, adhesion between th...

متن کامل

Posterior capsular opacification and intraocular lens surface micro-roughness characteristics: an atomic force microscopy study.

OBJECTIVE Surface roughness parameters of various intraocular lenses (IOLs) biomaterials using atomic force microscopy (AFM) are compared. Variation, if any, in the micro-roughness properties of different IOLs made up of the same biomaterial is also explored. Retrospective analysis of posterior capsular opacification (PCO) incidence has been followed up for a period of four years post IOL impla...

متن کامل

Supercritical Drug Impregnation onto Intraocular Lenses

Supercritical impregnation is an attractive “clean” alternative to conventional soaking into liquid process, using generally organic solvents. Impregnation process can be used for the development of controlled delivery systems that can be applied in pharmaceutical and medical fields. This work focuses on the preparation of controlled drug delivery systems for ophthalmic applications through sup...

متن کامل

Comparison of decentration and tilt between one piece and three piece polymethyl methacrylate intraocular lenses.

BACKGROUND The extent of the decentration and tilt was prospectively compared between one piece polymethyl methacrylate (PMMA) and three piece PMMA intraocular lenses (IOLs) which were implanted in the capsular bag after performing continuous curvilinear capsulorhexis. METHODS 91 patients underwent a one piece PMMA IOL implantation in one eye as well as the implantation of the three piece PMM...

متن کامل

Hydrophilic Acrylic versus PMMA Intraocular Lens Implantation in Pediatric Cataract Surgery

PURPOSE To compare primary implantation of foldable hydrophilic acrylic with polymethylmethacrylate (PMMA) intraocular lenses (IOLs) in pediatric cataract surgery in terms of short-term complications and visual outcomes. METHODS This randomized clinical trial included 40 eyes of 31 consecutive pediatric patients aged 1 to 6 years with unilateral or bilateral congenital cataracts undergoing ca...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Vision Research

دوره 35  شماره 

صفحات  -

تاریخ انتشار 1995