Investigation of Two Different Techniques for Accurate Measurements of Sinusoidal Signals

نویسندگان

  • Shereen M. El-Metwally
  • Mamdouh Halawa
چکیده

In this paper, two different techniques for the determination of the rms value of sinusoidal AC voltage at the range of 2V are practically compared: non-thermoelectric technique (via the direct measurement using a precise high sensitive digital voltmeter, and the comparison method using a precise AC voltage calibrator) and thermoelectric technique (via the null thermoelectric technique, and the algorithmic thermoelectric technique using a calibrated multijunction thermal converter (MJTC)). A series of comparisons between the four methods have been discussed and evaluated at frequencies from 20 Hz to 100 kHz to investigate the level of performance and competitiveness. The comparison results showed that the four applied methods agreed within values of 80μV ± 15μV/V and 68μV ± 11μV/V at frequencies of 20 Hz and 100 kHz, respectively. KeywordsAC voltage measurement, AC-DC thermal transfer, uncertainty budget, proficiency test.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of the Effect of Vanillin as a Green Corrosion Inhibitor for Stainless Steel Using Electrochemical Techniques

Vanillin offers interesting possibilities for corrosion inhibition because of its safe use and highsolubility in water. The effect of vanillin on the corrosion inhibition of AISI 304 stainless steel in0.5M H2SO4 solution has been studied using potentiodynamic polarization and electrochemicalimpedance spectroscopy (EIS). Furthermore, this paper demonstrates that the electrochemical noise(EN) tec...

متن کامل

Estimation of harmonic interference parameters of surface-NMR signal using an adaptive method and residual signal power

Surface nuclear magnetic resonance (surface-NMR) method is a well-known tool for determining the water-bearing layers and subsurface resistivity structure. Harmonic interference is an inevitable interference in surface-NMR measurements. Accurate estimation of harmonic interference parameters (i.e., fundamental frequency, phase and amplitude) leads to better retrieval of power-line harmonics and...

متن کامل

Translation Invariant Approach for Measuring Similarity of Signals

In many signal processing applications, an appropriate measure to compare two signals plays a fundamental role in both implementing the algorithm and evaluating its performance. Several techniques have been introduced in literature as similarity measures. However, the existing measures are often either impractical for some applications or they have unsatisfactory results in some other applicati...

متن کامل

Translation Invariant Approach for Measuring Similarity of Signals

In many signal processing applications, an appropriate measure to compare two signals plays a fundamental role in both implementing the algorithm and evaluating its performance. Several techniques have been introduced in literature as similarity measures. However, the existing measures are often either impractical for some applications or they have unsatisfactory results in some other applicati...

متن کامل

Evaluation of different clearing techniques: An auxiliary method for studying root canal anatomy

Evaluation of different clearing techniques: An auxiliary method for studying root canal anatomy Dr. M. Vatanpour* - Dr. M. Javidi** * Resident of Endodontics Dept., Faculty of Dentistry, Mashhad University of Medical Sciences. ** Assistant Professor of Endodontics Dept., Faculty of Dentistry, Mashhad University of Medical Sciences.Background and Aim: Various techniques for clearing the root ca...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013