Detection of focal hepatic lesions with MR imaging: prospective comparison of T2-weighted fast spin-echo with and without fat suppression, T2-weighted breath-hold fast spin-echo, and gadolinium chelate-enhanced 3D gradient-recalled imaging.

نویسندگان

  • P Soyer
  • S C de Givry
  • C Gueye
  • S Lenormand
  • E Somveille
  • A Scherrer
چکیده

OBJECTIVE The purpose of this study was to compare breath-hold three-dimensional (3D) rapid gradient-echo (GRE) MR imaging obtained before and after gadolinium chelate injection with T2-weighted fast spin-echo and T2-weighted breath-hold fast spin-echo (BHFSE) MR imaging in the detection of focal hepatic masses. SUBJECTS AND METHODS Fifty-three patients with 108 focal hepatic masses had, prospectively, MR of the liver at 1.5 T. T2-weighted fast spin-echo (6000/117 [TR/effective TE]; echo train length=16; acquisition time = 3 min 12 sec) images obtained with and without fat suppression, T2-weighted BHFSE (2700/105; echo train length = 20; acquisition time = 22 sec), and 3D rapid GRE images (10.1/1.9/30 degrees [TR/TE/alpha]) obtained during one breath-hold (12 scan locations in 21 sec or 20 scan locations in 32 sec) before and after injection of gadolinium chelate were blindly and independently analyzed in consensus by three readers. RESULTS Gadolinium chelate-enhanced 3D rapid GRE images allowed depiction of more focal hepatic masses (90 of 108, sensitivity = 83%) than did T2-weighted fast spin-echo with fat suppression images (76 of 108, sensitivity = 70%), T2-weighted fast spin-echo without fat suppression images (74 of 108, sensitivity = 69%), T2-weighted BHFSE images (73 of 108, sensitivity = 68%), and unenhanced 3D rapid GRE images (54 of 108, sensitivity = 50%) (p < .01). No difference in sensitivity was found between the three T2-weighted sequences. CONCLUSION Gadolinium chelate-enhanced 3D rapid GRE imaging is superior to T2-weighted fast spin-echo images obtained with or without fat suppression for the detection of focal hepatic masses. T2-weighted BHFSE is similar to T2-weighted fast spin-echo images in detecting focal hepatic lesions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison of MR sequences for lesions of the parotid gland.

PURPOSE To compare six MR sequences (plain and gadolinium-enhanced fat suppressed T1-weighted spin echo, T2-weighted standard spin echo, fat-suppressed and non-fat-suppressed T2-weighted fast spin echo, and inversion-recovery T2-weighted fast spin echo) in their ability to detect, delineate, and characterize lesions of the parotid gland. METHODS Fifty-eight parotid gland lesions imaged on 47 ...

متن کامل

Fast multiplanar spoiled gradient-recalled imaging of the liver: pulse sequence optimization and comparison with spin-echo MR imaging.

OBJECTIVE The purpose of this study was to optimize a new rapid-acquisition MR pulse sequence, called fast multiplanar spoiled gradient-recalled (FMPSPGR) imaging, for breath-hold imaging of the liver and to compare unenhanced and contrast-enhanced FMPSPGR with standard spin-echo imaging in detecting liver tumors. MATERIALS AND METHODS The pulse sequence was optimized at 1.5 T with a healthy ...

متن کامل

SSFSE MR Imaging of Focal Hepatic Lesions

With improvements in pulse sequence design and gradient amplifiers complete breath-hold MR imaging of the liver is possible enabling rapid evaluation, which is relatively free of motion artifacts. The combination of Single Shot Fast Spin-Echo (SSFSE) and Fast Multiplanar Spoiled Gradient-Echo(FMSPGR) sequences provide both breath-hold T2and TI-weighted non-contrast images, as well as multiphase...

متن کامل

Fat-suppressed MR of the orbit and cavernous sinus: comparison of fast spin-echo and conventional spin-echo.

PURPOSE To compare T2-weighted fat-suppressed fast spin-echo imaging with fat-suppressed conventional spin-echo imaging in the detection of normal intraorbital and pericavernous anatomy and orbital disease, and to determine the efficacy of fat saturation with T2-weighted fast spin-echo imaging of the cavernous sinus. METHODS Contrast-to-noise ratios of normal intraorbital anatomy were calcula...

متن کامل

Head and neck paragangliomas: improved tumor detection using contrast-enhanced 3D time-of-flight MR angiography as compared with fat-suppressed MR imaging techniques.

BACKGROUND AND PURPOSE MR imaging techniques have proved their efficacy in imaging the head and neck region. In this study, we compared T1-weighted, dual T2-weighted, and fat-suppressed MR imaging and unenhanced and contrast-enhanced 3D time-of-flight MR angiography sequences for detection of head and neck paragangliomas. METHODS Thirty-one patients with 70 paragangliomas were examined. Four ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJR. American journal of roentgenology

دوره 166 5  شماره 

صفحات  -

تاریخ انتشار 1996