Complete Blood Count Reference Intervals for Healthy Han Chinese Adults

نویسندگان

  • Xinzhong Wu
  • Min Zhao
  • Baishen Pan
  • Jie Zhang
  • Mingting Peng
  • Lanlan Wang
  • Xiaoke Hao
  • Xianzhang Huang
  • Runqing Mu
  • Wei Guo
  • Rui Qiao
  • Wenxiang Chen
  • Hong Jiang
  • Yueyun Ma
  • Hong Shang
چکیده

BACKGROUND Complete blood count (CBC) reference intervals are important to diagnose diseases, screen blood donors, and assess overall health. However, current reference intervals established by older instruments and technologies and those from American and European populations are not suitable for Chinese samples due to ethnic, dietary, and lifestyle differences. The aim of this multicenter collaborative study was to establish CBC reference intervals for healthy Han Chinese adults. METHODS A total of 4,642 healthy individuals (2,136 males and 2,506 females) were recruited from six clinical centers in China (Shenyang, Beijing, Shanghai, Guangzhou, Chengdu, and Xi'an). Blood samples collected in K2EDTA anticoagulant tubes were analyzed. Analysis of variance was performed to determine differences in consensus intervals according to the use of data from the combined sample and selected samples. RESULTS Median and mean platelet counts from the Chengdu center were significantly lower than those from other centers. Red blood cell count (RBC), hemoglobin (HGB), and hematocrit (HCT) values were higher in males than in females at all ages. Other CBC parameters showed no significant instrument-, region-, age-, or sex-dependent difference. Thalassemia carriers were found to affect the lower or upper limit of different RBC profiles. CONCLUSION We were able to establish consensus intervals for CBC parameters in healthy Han Chinese adults. RBC, HGB, and HCT intervals were established for each sex. The reference interval for platelets for the Chengdu center should be established independently.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hematological Reference Values for Healthy Males in the Central Part of Iran

  Background and Objectives: Laboratory reference values are an important tool for clinical management of patients. Reference values being used in most laboratories in Iran have been provided from the established reference values from developed countries. However, several variables can affect on these laboratory parameters. Therefore, this study was carried out to establish the reference value...

متن کامل

Reference intervals for a complete blood count determined on different automated haematology analysers: Abx Pentra 120 Retic, Coulter Gen-S, Sysmex SE 9500, Abbott Cell Dyn 4000 and Bayer Advia 120.

We processed 317 samples from healthy adult volunteers for a complete blood count, including leukocyte differentials and reticulocyte parameters, through five new-generation haematology analysers: Abx Pentra 120 Retic, Coulter Gen-S, Sysmex SE 9500, Abbott Cell Dyn 4000 and Bayer Advia 120. From these data non-parametric 2.5-97.5 percentile reference intervals were calculated for all parameters...

متن کامل

White blood cell counts in healthy Jamaican adults.

The investigation of presumed neutropenia places a burden on the health services, especially those of developing countries, including Jamaica. This may be because the normal ranges used in the laboratory are based on the values generated from the Caucasian population. Previous studies looking at African and Afro-Caribbean groups have found lower counts for these populations compared with Caucas...

متن کامل

Reference Values of Lymphocyte Sub-Populations in Healthy Human Immunodeficiency Virus-Negative Iranian Adults

Background: Lymphocyte subsets enumeration is considered prominent in the management of primary and acquired immunodeficiency disorders. Because of local variations due to race, age, gender, and environmental conditions on lymphocyte subsets, and to improve the accuracy of interpretation of laboratory findings, reference intervals must be determined in every population. Objective: To establish ...

متن کامل

Variables that affect platelet function analyzer-100 (PFA-100) closure times and establishment of reference intervals in Korean adults.

The PFA-100 is an in vitro system for measurement of platelet function in whole blood. To establish reference intervals in the Korean population, we investigated the relationships between PFA-100 closure times and gender, ABO blood group, citrate concentration, and time of blood collection in 120 well-characterized healthy Korean adults. Gender did not affect closure time values. Blood group O ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015