Abnormal operation behavior analysis and countermeasures on the differential protection of converter transformer ¬リニ
نویسندگان
چکیده
Intriguing mal-operations and fail-to-trip of the differential protection of the converter transformer in the HVDC system are reported. In this paper, the mechanism of these abnormal operation behaviors is analyzed. By virtue of deliberately designed models of the converter transformer and the HVDC transmission system, a variety of simulation tests are carried out and above mentioned strange operation behaviors can be recurred. Then, the conditions of the operating states and faults resulting in this sort of abnormal operations can be determined. The reasons rest with the deep saturation of core due to energization and the high second harmonic within the differential currents due to faults. To solve above problems, the characteristics of voltage and differential current of the converter transformer are studied. It is disclosed that the time difference between the sudden change of the phase voltage and the emergence of differential current exists due to switching-on of the converter transformer. However, this time difference does not exist for any cases due to internal faults. Based on this finding, a novel criterion is therefore proposed. And it is verified with extensive RTDS based simulation test results. 2014 Elsevier Ltd. All rights reserved.
منابع مشابه
A New Model for Analysis of Unusual Mal-Operation of Differential Protection Due to the Ultra-Saturation Phenomenon during the Loaded Power Transformer Energization
In this paper, a new model based on the thevenin equivalent circuit for investigating the ultra-saturation phenomenon during the energization of a loaded power transformer is presented and its effect on the differential protection of the transformer is considered. The ultra-saturation phenomenon causes the mal-operation of the power transformer differential protection. So, the description a...
متن کاملA New Model for Analysis of Unusual Mal-Operation of Differential Protection Due to the Ultra-Saturation Phenomenon during the Loaded Power Transformer Energization
In this paper, a new model based on the thevenin equivalent circuit for investigating the ultra-saturation phenomenon during the energization of a loaded power transformer is presented and its effect on the differential protection of the transformer is considered. The ultra-saturation phenomenon causes the mal-operation of the power transformer differential protection. So, the description a...
متن کاملDetermination of a new model to study ultra-saturation phenomenon during the loaded power transformer energization and its effect on differential protection
One of transient phenomenon that causes the mal-operation of the power transformer differential protection during the energization of a loaded power transformer is the ultra-saturation phenomenon. In this paper, a new model for investigating the ultra-saturation phenomenon during the energization of a loaded power transformer is presented and its effect on the differential protection of the pow...
متن کاملDetermination of a new model to study ultra-saturation phenomenon during the loaded power transformer energization and its effect on differential protection
One of transient phenomenon that causes the mal-operation of the power transformer differential protection during the energization of a loaded power transformer is the ultra-saturation phenomenon. In this paper, a new model for investigating the ultra-saturation phenomenon during the energization of a loaded power transformer is presented and its effect on the differential protection of the pow...
متن کاملEfficiency Improvement of the Flyback Converter Based on High Frequency Transformer Winding Rearrangement
In this paper, a novel method for loss reduction and efficiency optimization of the high frequency flyback transformers is proposed based on rearrangement of the windings. According to detailed analysis of the high frequency flyback transformer using FEM technique, a novel and simple approach for its design improvement and loss reduction is introduced. It is shown that leakage flux scattering i...