Aortic root geometry in aortic stenosis patients (a SEAS substudy).

نویسندگان

  • Edda Bahlmann
  • Christoph A Nienaber
  • Dana Cramariuc
  • Christa Gohlke-Baerwolf
  • Simon Ray
  • Richard B Devereux
  • Kristian Wachtell
  • Karl Heinz Kuck
  • Einar Davidsen
  • Eva Gerdts
چکیده

AIMS To report aortic root geometry by echocardiography in a large population of healthy, asymptomatic aortic stenosis (AS) patients in relation to current vendor-specified requirements for transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS Baseline data in 1481 patients with asymptomatic AS (mean age 67 years, 39% women) in the Simvastatin Ezetimibe in AS study were used. The inner aortic diameter was measured at four levels: annulus, sinus of Valsalva, sinotubular junction and supracoronary, and sinus height as the annulo-junctional distance. Analyses were based on vendor-specified requirements for the aortic root geometry for current available prostheses, CoreValve and Edwards-Sapien. The ratio of sinus of Valsalva height to sinus width was 1:2. In multivariate linear regression analysis, larger sinus of Valsalva height was associated with older age, larger sinus of Valsalva diameter, lower ejection fraction and smaller supracoronary diameter (multiple R(2) = 0.19, P< 0.01). The required annulus diameter for implantation of CoreValve was met in 61.9%, and for the Edwards-Sapien prosthesis in 66.9%. Overall, annular dimension feasible for TAVI using any available prosthesis was found in 78.2% of patients and in 77.7% of patients also the required minimum sinus of Valsalva height was found. Comparing the group of patients who met TAVI requirements to those who did not, the latter included more women and patients with lower body height and weight and significantly smaller aortic root diameters (all P < 0.05). CONCLUSION Among AS patients in the SEAS study, 27% of women and 19% of men did not have aortic root geometry fulfilling current requirements for TAVI.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SUPRAVALVAR AORTIC STENOSIS IN CHILDREN REPORT OF THIRTEEN CASES

During 15 years from 1975 to 1990, thirteen cases of supravalvar aortic stenosis were admitted at the pediatrics department of Shahid Rajai Heart Hospital, Tehran. All patients were subjected to cardiac catheterization and a angiocardiography. Patients ranged in age from 3.5 years to 14 years with a mean of 8.7 years. Seventy seven percent of childen were male. Eight cases (61.5%) had Wil...

متن کامل

مقایسه نتایج درمانی بالون والوپلاستی و والوتومی جراحی در بیماران مبتلا به تنگی مادرزادی دریچه آئورت در پیگیری 6 ساله در بخش کودکان بیمارستان قلب شهید رجایی تهران

Background: Balloon valvuloplasty is a relatively new technique for relief of obstruction of aortic valve. The primary results of this procedure are similar to surgical valvotomy with fewer complications and mortality. Materials and methods: One hundred fifty-five patients with congenital aortic stenosis were enrolled in this study over a period of 6 years (1991-1997). Participants were all un...

متن کامل

High sensitivity C reactive protein as a prognostic marker in patients with mild to moderate aortic valve stenosis during lipid-lowering treatment: an SEAS substudy

AIMS To assess the prognostic importance of high-sensitive C reactive protein (hsCRP) in patients with mild to moderate aortic valve stenosis during placebo or simvastatin/ezetimibe treatment in Simvastatin and Ezetimibe in Aortic Stenosis (SEAS). METHODS AND RESULTS In 1620 SEAS patients, we measured lipids and hsCRP at baseline and after 1 year of treatment and registered during 4 years of ...

متن کامل

Assessment of the aortic root using real-time 3D transesophageal echocardiography.

BACKGROUND Precise evaluation of the aortic root geometry prior to transcatheter aortic valve implantation is important for procedural success in patients with aortic stenosis (AS). To determine the potential for 3-dimensional transesophageal echocardiography (3DTEE), the aims of the present study were: (1) to assess the accuracy of 3DTEE measurements of the aortic root using multidetector comp...

متن کامل

Bicuspid Aortic Valve: An Unusual Cause of Aneurysm of Left Coronary Sinus of Valsalva

Bicuspid aortic valve is traditionally considered an innocuous congenital anomaly. Due to a better and widespread availability of non-invasive imaging techniques, it has come to the fore that 30% of these cases develop complications, viz., valve abnormality (aortic regurgitation and stenosis), and aneurysm of aortic root and ascending aorta. Sinus of Valsalva aneurysm is an uncommon complicatio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology

دوره 12 8  شماره 

صفحات  -

تاریخ انتشار 2011