Endovascular treatment of false-aneurysm ten years after dacron patch aortoplasty for coarctation of the aortic isthmus. Report of a case.
نویسندگان
چکیده
False aneurysm degeneration is a known complication of patch aortoplasty for coarctation of the aortic isthmus. Open surgical treatment consists of prosthetic graft repair of the involved aorta, often requires circulatory arrest to achieve a safe proximal aortic control and perform proximal anastomosis, and finally is associated with substantial perioperative morbidity. Endografting of the diseased aorta is a valuable alternative to open repair, when feasible, with good short and long term results. We now report one more case of false aneurysm ten years after Dacron patch aortoplasty for isthmic coarctation in a 26-year-old woman, successfully treated by endovascular repair via the left common iliac artery, and a complete exclusion of the aneurysm at two year follow-up.
منابع مشابه
AORTIC TRANSECTION AND ITS SURGICAL REPAIR: A CASE REPORT FROM IRAN
Aortic transection is a rare but life-threatening complication of blunt chest trauma. Treatment options include open repair, medical management and most recently, endovascular repair. We report a 33 years old male with a traumatic aortic transection following a car accident. Aortic injury and its pseudo-aneurysm were confirmed by Chest CT scan and TEE in the descending thoracic aorta just belo...
متن کاملAn Aortoenteric Fistula Arising after Endovascular Management of a Mycotic Abdominal Aortic Aneurysm Complicated with a Psoas Abscess
Mycotic aortic aneurysms account for 1–3% of all aortic aneurysms. The management of this disease is controversial. Since open surgical repair is associated with high morbidity and mortality rates, endovascular aneurysm repair is an alternative treatment method with promising early and midterm outcomes, although its long-term durability is unknown.Secondary aortoenteric fistulas may occur iatro...
متن کاملFalse aortic aneurysm at site of previous coarctation repair: the role of cardiovascular magnetic resonance.
We describe a 37-year-old who presented with hemoptysis. Twenty-one years previously he had undergone Dacron patch aortoplasty for coarctation. Initial investigations failed to reveal the cause of the hemoptysis. Cardiovascular magnetic resonance (CMR) demonstrated an aneurysm at the site of the repair. He underwent successful repair of the aneurysm with a Gelseal interpositional graft.
متن کاملPii: S1010-7940(02)00664-4
This report describes the formation of a true aneurysm 15 years after an internal mammary artery patch aortoplasty of an aortic coarctation. A true aneurysm was confirmed on histology. To our knowledge, this is the first report of a case with such a complication. q 2002 Published by Elsevier Science B.V.
متن کاملBULL ET-INDUCED FALSE ANEURYSM OF THORACIC AORTA WITH A TEN YEAR LATENCY PERIOD IN A VICTIM OF THE IRAN-IRAQ WAR: REPORT OF A CASE
Traumatic false aneurysm of the thoracic aorta is not uncommon. But accordingly this case is unusual in its ten year delay between injury and presentation and treatment. A victim of the Iran-Iraq war is presented with a false aneurysm of the thoracic aorta ten years after a bullet injury to the chest and thoracic spine. Penetrating chest wounds, mechanisms of injury and diagnosis are also ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annali italiani di chirurgia
دوره 84 4 شماره
صفحات -
تاریخ انتشار 2013