Title: a High-density Erp Study Reveals Latency, Amplitude, and Topographical Reilly (ebiomed: Ehealthcare Based on Biomedical Signal Processing and Ict for Integrated Diagnosis and Treatment of Disease)

نویسندگان

  • R. Whelan
  • R. Lonergan
  • H. Kiiski
  • H. Nolan
  • K. Kinsella
  • J. Bramham
  • M. O’Brien
  • R. B. Reilly
  • M. Hutchinson
  • N. Tubridy
چکیده

Objective. To quantify latency, amplitude and topographical differences in event-related potential (ERP) components between multiple sclerosis (MS) patients and controls and to compare ERP findings with results from the paced auditory serial addition test (PASAT). Methods. Fifty-four subjects (17 relapsing remitting (RRMS) patients, 16 secondary progressive (SPMS) patients, and 21 controls) completed visual and auditory oddball tasks while data were recorded from 134 EEG channels. Latency and amplitude differences, calculated using composite mean amplitude measures, were tested using an ANOVA. Topographical differences were tested using statistical parametric mapping (SPM). Results. In the visual modality, P2, P3 amplitudes and N2 latency were significantly different across groups. In the auditory modality, P2, N2, and P3 latencies and N1 amplitude were significantly different across groups. There were no significant differences between RRMS and SPMS patients on any ERP component. There were topographical differences between MS patients and controls for both early and late components for the visual modality, but only in the early components for the auditory modality. PASAT score correlated significantly with auditory P3 latency for MS patients. Conclusions. There were significant ERP differences between MS patients and controls. Significance. The present study indicated that both early sensory and later cognitive ERP components are impaired in MS patients relative to controls.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impaired information processing speed and attention allocation in multiple sclerosis patients versus controls: a high-density EEG study.

BACKGROUND The no-go P3a is a variant of the P300 event-related potential (ERP) that indexes speed of information processing and attention allocation. The aim of this study was to compare ERP findings with results from the paced auditory serial addition test (PASAT) and to quantify latency, amplitude and topographical differences in P3a ERP components between multiple sclerosis (MS) patients an...

متن کامل

تغییرات مؤلفه های فرکانسی و زمانی الکترورتینوگرام در بیماران مبتلا به رتینیت پیگمنتوزا در مقایسه با افراد سالم

Background and purpose: Retinitis Pigmentosa (RP) is one of the retinal degeneration diseases affecting the eye signals. Electroretinogram (ERG) is a signal that plays an important role in diagnosis and treatment of RP. This signal includes useful information that cannot be revealed just in time domain. We aimed to investigate the effect of RP on time, frequency, and time-frequency parameters o...

متن کامل

Design and Implementation of Digital Demodulator for Frequency Modulated CW Radar (RESEARCH NOTE)

Radar Signal Processing has been an interesting area of research for realization of programmable digital signal processor using VLSI design techniques. Digital Signal Processing (DSP) algorithms have been an integral design methodology for implementation of high speed application specific real-time systems especially for high resolution radar. CORDIC algorithm, in recent times, is turned out to...

متن کامل

Diagnosis of COVID-19 Disease Using Lung CT-scan Image Processing Techniques

Introduction: Today, several methods are used for detecting COVID-19 such as disease-related clinical symptoms, and more accurate diagnostic methods like lung CT-scan imaging. This study aimed to achieve an accurate diagnostic method for intelligent and automatic diagnosis of COVID-19 using lung CT-scan image processing techniques and utilize the results of this method as an accurate diagnostic...

متن کامل

Diagnosis of COVID-19 Disease Using Lung CT-scan Image Processing Techniques

Introduction: Today, several methods are used for detecting COVID-19 such as disease-related clinical symptoms, and more accurate diagnostic methods like lung CT-scan imaging. This study aimed to achieve an accurate diagnostic method for intelligent and automatic diagnosis of COVID-19 using lung CT-scan image processing techniques and utilize the results of this method as an accurate diagnostic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010