Photoacoustic tomography of vascular compliance in humans.

نویسندگان

  • Pengfei Hai
  • Yong Zhou
  • Jinyang Liang
  • Chiye Li
  • Lihong V Wang
چکیده

Characterization of blood vessel elastic properties can help in detecting thrombosis and preventing life-threatening conditions such as acute myocardial infarction or stroke. Vascular elastic photoacoustic tomography (VE-PAT) is proposed to measure blood vessel compliance in humans. Implemented on a linear-array-based photoacoustic computed tomography system, VE-PAT can quantify blood vessel compliance changes due to simulated thrombosis and occlusion. The feasibility of the VE-PAT system was first demonstrated by measuring the strains under uniaxial loading in perfused blood vessel phantoms and quantifying their compliance changes due to the simulated thrombosis. The VE-PAT system detected a decrease in the compliances of blood vessel phantoms with simulated thrombosis, which was validated by a standard compression test. The VE-PAT system was then applied to assess blood vessel compliance in a human subject. Experimental results showed a decrease in compliance when an occlusion occurred downstream from the measurement point in the blood vessels, demonstrating VE-PAT’s potential for clinical thrombosis detection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Imaging of tumor angiogenesis in rat brains in vivo by photoacoustic tomography.

Green laser pulses at a wavelength of 532 nm from a Q-switched Nd:YAG laser were employed as irradiation sources for photoacoustic tomography (PAT). The vascular structure of the brain was imaged clearly, with optimal contrast, because blood has strong absorption near this wavelength. The photoacoustic images of rat brain tumors in this study clearly reveal the angiogenesis that is associated w...

متن کامل

In vivo longitudinal photoacoustic imaging of subcutaneous tumours in mice

Photoacoustic tomography can provide high resolution 3D images of vascular networks, making it well suited to characterising the development of tumour vasculature and its response to treatment. In this study, photoacoustic images to depths of up to 9 mm were obtained using an all optical ultrasound detection scheme. Two type of colorectal tumours (LS174T and SW1222) implanted subcutaneously in ...

متن کامل

Retrospective respiration-gated whole-body photoacoustic computed tomography of mice.

Photoacoustic tomography (PAT) is an emerging technique that has a great potential for preclinical whole-body imaging. To date, most whole-body PAT systems require multiple laser shots to generate one cross-sectional image, yielding a frame rate of <1  Hz. Because a mouse breathes at up to 3 Hz, without proper gating mechanisms, acquired images are susceptible to motion artifacts. Here, we intr...

متن کامل

Special section guest editorial: Photons plus ultrasound: imaging and sensing.

m: http://biomedicaloptics.spiedigitallibrary.org/ on 05/11/2016 Terms of Use Fig. 1 . As of 2009, this conference has become the largest at SPIE Photonics West. Hybrid modalities such as photoacoustic or optoacoustic tomography can provide deep tissue penetration, high ultrasonic resolution, and speckle-free optical contrast. Applications include in vivo functional and molecular imaging of can...

متن کامل

Noninvasive photoacoustic computed tomography of mouse brain metabolism in vivo

We have demonstrated the feasibility of imaging mouse brain metabolism using photoacoustic computed tomography (PACT), a fast, noninvasive and functional imaging modality with optical contrast and acoustic resolution. Brain responses to forepaw stimulations were imaged transdermally and transcranially. 2-NBDG, which diffuses well across the blood-brain-barrier, provided exogenous contrast for p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 20 12  شماره 

صفحات  -

تاریخ انتشار 2015