Bunch mode specific rate corrections for PILATUS3 detectors
نویسندگان
چکیده
PILATUS X-ray detectors are in operation at many synchrotron beamlines around the world. This article reports on the characterization of the new PILATUS3 detector generation at high count rates. As for all counting detectors, the measured intensities have to be corrected for the dead-time of the counting mechanism at high photon fluxes. The large number of different bunch modes at these synchrotrons as well as the wide range of detector settings presents a challenge for providing accurate corrections. To avoid the intricate measurement of the count rate behaviour for every bunch mode, a Monte Carlo simulation of the counting mechanism has been implemented, which is able to predict the corrections for arbitrary bunch modes and a wide range of detector settings. This article compares the simulated results with experimental data acquired at different synchrotrons. It is found that the usage of bunch mode specific corrections based on this simulation improves the accuracy of the measured intensities by up to 40% for high photon rates and highly structured bunch modes. For less structured bunch modes, the instant retrigger technology of PILATUS3 detectors substantially reduces the dependency of the rate correction on the bunch mode. The acquired data also demonstrate that the instant retrigger technology allows for data acquisition up to 15 million photons per second per pixel.
منابع مشابه
Empirical dead-time corrections for energy-resolving detectors at synchrotron sources
We examine the high count-rate performance of an energy-resolving detector in the three operating modes of the Advanced Photon Source (APS). Specifically, we present the optimal dead-time corrections for the SII Vortex silicon drift diode (SDD) detector using a digital pulse processor, highlighting the differences in operation between the 24-bunch, 324-bunch, and hybrid singlet modes of the APS...
متن کاملSimultaneous Detection of Longitudinal and Transverse Bunch Signals at Anka
The ANKA storage ring offers different operation modes including the short-bunch mode with bunch lengths tuned down to a few picoseconds. This can lead to the occurrence of micro-bunching instabilities coupled to the emission of coherent synchrotron radiation (CSR) in so-called ’bursts’. To study this CSR instability we use several turn-by-turn enabled detector systems to synchronously measure ...
متن کاملPulse-resolved multi-photon X-ray detection at 31 MHz based on a quadrant avalanche photodiode
The technical realisation and the commissioning experiments of a high-speed X-ray detector based on a quadrant avalanche silicon photodiode and high-speed digitizers are described. The development is driven by the need for X-ray detectors dedicated to time-resolved diffraction and imaging experiments, ideally requiring pulse-resolved data processing at the synchrotron bunch repetition rate. By ...
متن کاملLARGE-AREA CdTe PIXEL DETECTORS FOR HIGH-ENERGY X-RAY DIFFRACTION APPLICATIONS
Already a while ago researchers in pharmaceutical science have recognized hard X-rays as an useful analytical tool. Computed tomography techniques (CT) were utilized to investigate porosity and morphology of granules [1] and density variations within tablets [2]; real-time X-Ray Powder Diffraction (XRPD) techniques revealed reaction mechanisms and metastable phases of pharmaceutical cocrystals ...
متن کاملDesign for a Longitudinal Density Monitor for the Lhc
Synchrotron radiation is currently used on the LHC for beam imaging and for monitoring the proton population in the 3 microsecond abort gap. In addition to these existing detectors, a study has been initiated to provide longitudinal density profiles of the LHC beams with a high dynamic range and a 50ps time resolution. This would allow for the precise measurement both of the bunch shape and the...
متن کامل