Comparison of airway pressure release ventilation to conventional mechanical ventilation in the early management of smoke inhalation injury in swine.
نویسندگان
چکیده
OBJECTIVE The role of airway pressure release ventilation in the management of early smoke inhalation injury has not been studied. We compared the effects of airway pressure release ventilation and conventional mechanical ventilation on oxygenation in a porcine model of acute respiratory distress syndrome induced by wood smoke inhalation. DESIGN Prospective animal study. SETTING Government laboratory animal intensive care unit. PATIENTS Thirty-three Yorkshire pigs. INTERVENTIONS Smoke inhalation injury. MEASUREMENTS AND MAIN RESULTS Anesthetized female Yorkshire pigs (n = 33) inhaled room-temperature pine-bark smoke. Before injury, the pigs were randomized to receive conventional mechanical ventilation (n = 15) or airway pressure release ventilation (n = 12) for 48 hrs after smoke inhalation. As acute respiratory distress syndrome developed (PaO2/Fio2 ratio <200), plateau pressures were limited to <35 cm H2O. Six uninjured pigs received conventional mechanical ventilation for 48 hrs and served as time controls. Changes in PaO2/Fio2 ratio, tidal volume, respiratory rate, mean airway pressure, plateau pressure, and hemodynamic variables were recorded. Survival was assessed using Kaplan-Meier analysis. PaO2/Fio2 ratio was lower in airway pressure release ventilation vs. conventional mechanical ventilation pigs at 12, 18, and 24 hrs (p < .05) but not at 48 hrs. Tidal volumes were lower in conventional mechanical ventilation animals between 30 and 48 hrs post injury (p < .05). Respiratory rates were lower in airway pressure release ventilation at 24, 42, and 48 hrs (p < .05). Mean airway pressures were higher in airway pressure release ventilation animals between 6 and 48 hrs (p < .05). There was no difference in plateau pressures, hemodynamic variables, or survival between conventional mechanical ventilation and airway pressure release ventilation pigs. CONCLUSIONS In this model of acute respiratory distress syndrome caused by severe smoke inhalation in swine, airway pressure release ventilation-treated animals developed acute respiratory distress syndrome faster than conventional mechanical ventilation-treated animals, showing a lower PaO2/Fio2 ratio at 12, 18, and 24 hrs after injury. At other time points, PaO2/Fio2 ratio was not different between conventional mechanical ventilation and airway pressure release ventilation.
منابع مشابه
P32: Effect of Airway Pressure Release Ventilation Mode on Intracranial Pressure and Oxygenation in Patients with Traumatic Brain Injuries
This study aimed at compare influences of airway pressure release ventilation (APRV) and Synchronized Intermittent Mechanical Ventilation (SIMV) on intracranial pressure and oxygenation status in patients with traumatic brain injuries. A clinical trial was carried out in 40 patients with traumatic brain injuries in the intensive care unit in Kamyab neurosurgery Hospital, Mashhad, Iran. The pati...
متن کاملA Comparison between Nasal Intermittent Positive Pressure Ventilation and Nasal Continuous Positive Airway Pressure Ventilation in the Treatment of Neonatal Respiratory Distress Syndrome
Background: Nasal intermittent positive pressure ventilation (NIPPV) is a non-invasive ventilatory mode, which delivers mechanical ventilation via nasal tubes or prongs. The present study was conducted to compare the efficacy of NIPPV and nasal continuous positive airway pressure ventilation (NCPAP) in reducing the need for intubation in preterm infants with respiratory distress syndrome (RDS)....
متن کاملNew modalities of mechanical ventilation: high-frequency oscillatory ventilation and airway pressure release ventilation.
Management of acute lung injury (ALI) and the acute respiratory distress syndrome (ARDS) is largely supportive, with the use of mechanical ventilation being a central feature. Recent advances in the understanding of ALI/ARDS and mechanical ventilation have revealed that lung-protective ventilation strategies may attenuate ventilator-associated lung injury and improve patient morbidity/mortality...
متن کاملDoes Airway Pressure Release Ventilation Mode Make Difference in Cardiopulmonary Function of ICU Patients?
Introduction: Tuberculosis (TB), with different types of respiratory tract involvements, has a high rate of mortality all around the world. Endobronchial involvement, which is a slightly common tuberculous infection, requires special attention due to its severe complications such as bronchostenosis. Aim of study of this study was describes, one type of pulmonary tuberculosis with less diagnosed...
متن کاملVentilator management for hypoxemic respiratory failure attributable to H1N1 novel swine origin influenza virus.
Novel H1N1 swine origin influenza virus has led to a worldwide pandemic. During the pandemic, a significant number of patients became critically ill primarily because of respiratory failure. Most of these patients required intubation and mechanical ventilation and were treated with conventional modes of mechanical ventilation using a lung-protective strategy with low tidal volumes, plateau pres...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Critical care medicine
دوره 39 10 شماره
صفحات -
تاریخ انتشار 2011