Biomechanical Comparison of Fully-Threaded Solid Cortical versus Partially-Threaded Cannulated Cancellous Screw Fixation for the Treatment of Lisfranc Injuries

نویسنده

  • Joshua Rozell
چکیده

109 retrieved after testing and subjected to threepoint bending (Figure 1B) and pull-out tests (Figure 1C) to elucidate differences in relevant performance characteristics. One-tailed paired student’s t-tests were used to evaluate the injuries applied to the specimens. For all other tests in this study, two-tailed, two-sample, equal variance t-tests were used with significance levels set at p=0.05.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical comparison of first metatarsophalangeal joint arthrodeses using triple-threaded headless screws versus partially threaded lag screws.

BACKGROUND Triple-threaded, cannulated headless screws of varying thread diameters and pitch are designed to maintain thread length across the arthrodesis plane, provide joint compression, and reduce countersinking. This study tested the biomechanical fixation strength of conventional partially threaded lag screws compared to triple-threaded headless screws in first metatarsophalangeal joint ar...

متن کامل

Latarjet Fixation: A Cadaveric Biomechanical Study Evaluating Cortical and Cannulated Screw Fixation.

BACKGROUND Attritional bone loss in patients with recurrent anterior instability has successfully been treated with a bone block procedure such as the Latarjet. It has not been previously demonstrated whether cortical or cancellous screws are superior when used for this procedure. PURPOSE To assess the strength of stainless steel cortical screws versus stainless steel cannulated cancellous sc...

متن کامل

Cannulated cancellous screw fixation for capitellum fractures in adolescents.

PURPOSE To review the outcome of 9 adolescents treated with 2 to 3 cannulated cancellous screws for type-1 capitellum fractures. METHODS Records of 8 boys and one girl aged 12 to 14 (mean, 14) years with type-1 capitellum fractures were reviewed. The mechanism of injury was a fall on the flexed elbow. No patient had associated injuries or neurovascular compromise. In 2 patients, the fracture ...

متن کامل

Arthroscopic Bony Bankart Repair Using Double-Threaded Headless Screw: A Case Report

We present a case of arthroscopic fixation for bony Bankart lesion using a double-threaded cannulated screw. A 39-year-old man sustained a left shoulder injury from a motorcycle accident. Radiographs showed bony Bankart lesion and CT revealed 40% defect of glenoid articular surface. Arthroscopic fixation was performed using double-threaded cannulated screw after the bony fragment was reduced by...

متن کامل

Short versus long thread cannulated cancellous screws for intracapsular hip fractures: a randomised trial of 432 patients.

It is unclear which length of thread may be most advantageous for the internal fixation of an intracapsular fracture with cancellous screws. We have compared the 16 mm versus the 32 mm threads on cancellous screws within a randomised trial for 432 patients. All fractures were fixed with three screws and patients followed-up for a minimum of one year from injury. The characteristics of the patie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017