Scattering error corrections for in situ absorption and attenuation measurements.

نویسندگان

  • David McKee
  • Jacek Piskozub
  • Ian Brown
چکیده

Monte Carlo simulations are used to establish a weighting function that describes the collection of angular scattering for the WETLabs AC-9 reflecting tube absorption meter. The equivalent weighting function for the AC-9 attenuation sensor is found to be well approximated by a binary step function with photons scattered between zero and the collection half-width angle contributing to the scattering error and photons scattered at larger angles making zero contribution. A new scattering error correction procedure is developed that accounts for scattering collection artifacts in both absorption and attenuation measurements. The new correction method does not assume zero absorption in the near infrared (NIR), does not assume a wavelength independent scattering phase function, but does require simultaneous measurements of spectrally matched particulate backscattering. The new method is based on an iterative approach that assumes that the scattering phase function can be adequately modeled from estimates of particulate backscattering ratio and Fournier-Forand phase functions. It is applied to sets of in situ data representative of clear ocean water, moderately turbid coastal water and highly turbid coastal water. Initial results suggest significantly higher levels of attenuation and absorption than those obtained using previously published scattering error correction procedures. Scattering signals from each correction procedure have similar magnitudes but significant differences in spectral distribution are observed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical closure in marine waters from in situ inherent optical property measurements.

Optical closure using radiative transfer simulations can be used to determine the consistency of in situ measurements of inherent optical properties (IOPs) and radiometry. Three scattering corrections are applied to in situ absorption and attenuation profile data for a range of coastal and oceanic waters, but are found to have only very limited impact on subsequent closure attempts for these st...

متن کامل

A New Approach for Scatter Removal and Attenuation Compensation from SPECT/CT Images

  Objective(s): In SPECT, the sinogram contains scatter and lack of attenuated counts that degrade the reconstructed image quality and quantity. Many techniques for attenuation and scatter correction have been proposed. An acceptable method of correction is to incorporate effects into an iterative statistical reconstruction. Here, we propose new Maximum Likelihood Expectation Maximiz...

متن کامل

Determination of absorption coefficients in highly scattering media from changes in attenuation and phase.

The accurate, quantitative analysis of absorption and scattering properties in tissue is a central problem in biochemical optics, in particular for the determination of hemoglobin and oxyhemoglobin concentrations. Because of light scattering, the absolute concentrations of these chromophores (i.e., the absorption coefficient) cannot easily be inferred. A new method for the estimation of the abs...

متن کامل

Semi-empirical correction algorithm for AC-9 measurements in a coccolithophore bloom.

Values for the coefficients of absorption (a) and attenuation (c) obtained from AC-9 measurements in coccolithophore blooms do not provide satisfactory inputs for radiance transfer models. We have therefore modified the standard AC-9 scattering correction algorithm by including an extra term, F(lambda, lambda(r)), which allows for possible wavelength dependence in the scattering phase function....

متن کامل

In-situ Attenuation Corrections for Radiation Force Measurements of High Frequency Ultrasound With a Conical Target

Radiation force balance (RFB) measurements of time-averaged, spatially-integrated ultrasound power transmitted into a reflectionless water load are based on measurements of the power received by the RFB target. When conical targets are used to intercept the output of collimated, circularly symmetric ultrasound sources operating at frequencies above a few megahertz, the correction for in-situ at...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optics express

دوره 16 24  شماره 

صفحات  -

تاریخ انتشار 2008