Plaque removal efficacy of oscillating-rotating power toothbrushes: review of six comparative clinical trials.

نویسندگان

  • Julie Grender
  • Karen Williams
  • Pat Walters
  • Malgorzata Klukowska
  • Hansjoerg Reick
چکیده

PURPOSE This review of six clinical trials provides a comprehensive overview of the results of statistical analyses to explore between-brush differences, specifically in the lingual, gingival marginal, and approximal ("hard-to-clean") areas, in post-brushing plaque removal of oscillating-rotating (O-R) power toothbrushes compared to either a marketed sonic power toothbrush or a manual toothbrush control. METHODS All studies were single-center, randomized and controlled, and examiner-blind. Four trials were four-period crossover design with replicate single-use brushing, while two studies were parallel group investigations (4 or 12 weeks) with multiple brushings and assessments at each visit. Generally healthy subjects were enrolled. Plaque evaluations were via the Turesky Modification of the Quigley-Hein Plaque Index (TMQHPI) or the Rustogi Modification of the Navy Plaque Index (RMNPI). At each evaluation visit, subjects brushed with either the randomly assigned O-R power brush [Oral-B Professional Care Series 4000 (Triumph) or Oral-B Vitality with Floss Action or Precision Clean brush head] or a control brush [Sonicare FlexCare with ProResults brush head (three trials) or an American Dental Association (ADA) reference manual toothbrush (three trials)]. ANCOVA and ANOVA analyses subsequently evaluated specifically the 'hard-to-clean' tooth surfaces for between-brush differences. RESULTS In total, 462 subjects completed the trials and were evaluable. While all toothbrushes provided significant post-brushing versus baseline plaque removal efficacy, the magnitude of the reduction was consistently superior for the O-R brush compared to either the sonic power or manual brush control in all the 'hard-to-clean" region-specific analyses. Adjusted mean RMNPI or TMQHPI benefits favoring the O-R brush relative to the sonic brush control were collectively 18% to 34% greater on lingual surfaces (P < or = 0.044), 32% to 49% greater on lingual approximal surfaces (P < 0.001), and 32% and 31% greater in lingual mandibular and lingual mandibular anterior regions, respectively (P < or = 0.005). Post-brushing whole mouth adjusted mean reduction RMNPI or TMQHPI benefits favoring the O-R brush compared to the manual brush control were collectively 31% to 206% greater on lingual surfaces (P < or = 0.001), 29% to 217% greater on lingual approximal surfaces (P < or = 0.001), and 67% to 526% greater in lingual gingival margin regions, respectively (P < or = 0.001). All study toothbrushes were well-tolerated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A novel oscillating-rotating power toothbrush with SmartGuide: designed for enhanced performance and compliance.

AIM The aim of this article is to provide a review of common power toothbrush technologies with a focus on the oscillating-rotating motion used in a novel toothbrush; describe features to drive compliance such as the "SmartGuide" innovation; and finally recommend steps to motivate patients to adopt a power toothbrush as part of their home care regimen. BACKGROUND Contemporary power toothbrush...

متن کامل

A comparative clinical study of extrinsic tooth stain removal with two electric toothbrushes [Braun D7 and D9] and a manual brush.

PURPOSE To evaluate the efficacy and safety of two oscillating/rotating toothbrushes, (Braun Oral-B Plaque Remover-D7 and Braun Oral-B Ultra Plaque Remover-D9) and a manual toothbrush with respect to removing extrinsic dental stain. MATERIALS AND METHODS This randomized, three-way cross-over study investigated 24 subjects entering the trial, which was divided into three, 5-day periods. Over t...

متن کامل

A randomized clinical trial comparing plaque removal efficacy of an oscillating-rotating power toothbrush to a manual toothbrush by multiple examiners.

OBJECTIVE To determine whether multiple examiners can demonstrate consistent plaque removal advantages for an oscillating-rotating power toothbrush versus a manual toothbrush. METHODS This was a replicate-use, single brushing, examiner-blind, randomized, two-treatment, four-period crossover clinical trial involving four examiners. Subjects were randomized to one of four treatment sequences in...

متن کامل

A robot comparison of efficacy of battery toothbrushes

This laboratory study to compare the cleaning efficacy of battery-operated power toothbrushes was carried out in two phases. Firstly, the Braun Oral-B D4/EB4 was compared with the Colgate Actibrush and secondly the D4/EB4 was compared with the Dr. Best Powerclean. All three brushes are battery-operated and have a small round brushhead with an oscillating/rotating action. They differ, however, w...

متن کامل

The clinical effectiveness of a novel power toothbrush and its impact on oral health.

This review details the invention and clinical testing of a new power toothbrush designed to provide a low cost, effective toothbrush, which has a combination of a round oscillating head in conjunction with fixed bristles. The data demonstrate this power toothbrush (Crest SpinBrush) is an effective cleaning toothbrush with respect to plaque removal. Four independent 4-period crossover studies, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of dentistry

دوره 26 2  شماره 

صفحات  -

تاریخ انتشار 2013