Comparison of dynamic and locked compression plates for treating midshaft clavicle fractures.
نویسندگان
چکیده
The purpose of this study was to compare the parameters of perioperative course and cost-effectiveness for patients with midshaft clavicle fractures treated by dynamic compression plates or locked compression plates.This retrospective, case-controlled study involved 54 patients with midshaft clavicle fractures who received dynamic compression plates (n=21) or locked compression plates (n=33) between January 2002 and December 2008. Indications for surgery included displacement or shortening >2 cm, comminuted fractures, and skin tenting. Patients with previous malunion, nonunion, multiple injuries of the shoulder girdle, or open fractures were excluded. Preoperative demographics showed no statistically significant differences between the 2 groups. Eighteen patients with dynamic compression plates and 28 patients with locked compression plates with postoperative follow-up >1 year were included for comparison. Statistical analyses for operative time, blood loss, complication rate, hospital stay, and union rate demonstrated no statistically significant difference between the 2 groups. The only statistically significant difference was a higher rate of plate removal requests in the dynamic compression plate group. Considering medical expenditure, locked compression plates cost 6 times more than dynamic compression plates in the authors' institution (US $600 vs $100, respectively).Other than more plate removal requests in the dynamic compression plate group and greater expense in the locked compression plate group, dynamic compression plates and locked compression plates achieved satisfactory operative outcomes in treating midshaft clavicle fractures, with no statistically significant difference between perioperative course and eventual fracture union observed between the 2 groups.
منابع مشابه
Does plate type influence the clinical outcomes and implant removal in midclavicular fractures fixed with 2.7-mm anteroinferior plates? A retrospective cohort study
BACKGROUND The purpose of this study was to evaluate surgical healing rates, implant failure, implant removal, and the need for surgical revision with regards to plate type in midshaft clavicle fractures fixed with 2.7-mm anteroinferior plates utilizing modern plating techniques. METHODS This retrospective exploratory cohort review took place at a level I teaching trauma center and a single l...
متن کاملUnicortical versus bicortical locked plate fixation in midshaft clavicle fractures.
Higher rates of poor outcomes in displaced midshaft clavicle fractures treated nonoperatively have recently been reported. Along with expanding indications for operative fixation and increasing application of locked plate constructs, it is unknown whether complications related to bicortical penetration of the clavicle can be avoided using unicortical fixation. The purpose of this study is to co...
متن کاملRole of autologous bone graft in the surgical treatment of atrophic nonunion of midshaft clavicular fractures.
A retrospective study was conducted to evaluate the role of autologous bone graft in treating atrophic nonunion of midshaft clavicle fracture with a limited-contact dynamic compression plate (LC-DCP). Between 1995 and 2008, sixty cases of atrophic nonunion of midshaft clavicle fractures were managed with open reduction and internal fixation with an LC-DCP. The cases were separated into 2 groups...
متن کاملArthroscopically Assisted Fixation of Unstable Distal Third Clavicle Fractures
INTRODUCTION Clavicle fractures are common injuries, representing 35 to 45% of fractures of the shoulder girdle. Fifteen to 25% of those involve the distal portion of the clavicle. Previously, non-operative management of midshaft clavicle fractures was based on the premise that even grossly malunited fractures had a minimal impact on functional outcomes. However, level I evidence supports the i...
متن کاملTitanium Elastic Nail (TEN) versus Reconstruction Plate Repair of Midshaft Clavicular Fractures: A Finite Element Study
BACKGROUND The biomechanical characteristics of midshaft clavicular fractures treated with titanium elastic nail (TEN) is unclear. This study aimed to present a biomechanical finite element analysis of biomechanical characteristics involved in TEN fixation and reconstruction plate fixation for midshaft clavicular fractures. METHODS Finite element models of the intact clavicle and of midshaft ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Orthopedics
دوره 35 5 شماره
صفحات -
تاریخ انتشار 2012