Optical In-Situ Measurement of Relative Deformations of the LHC Main Dipole Cold Masses
نویسندگان
چکیده
The LHC cryodipoles are composed of an evacuated cryostat and a cold mass, which is cooled by superfluid helium at 1.9 K. To obey constraints imposed by beam dynamics the particle beams must be centered within the mechanical axis of the dipole with a sub-millimeter accuracy. This requires in turn that the relative displacements between the cryostat and the cold mass must be monitored with accuracy at all times. Because of the extreme environmental conditions (the displacement must be measured in vacuum and between two points at a temperature difference of about 300 degrees), no adequate existing monitoring system was found for this application. We describe here a novel optical sensor developed for our scope and we present results of measurements made during the cold test of the dipoles.
منابع مشابه
Automation of 3d Measurements for the Final Assembly Steps of the Lhc Dipole Magnets
Due to the mechanical and beam optics requirements, the geometry of the LHC dipole cold masses is submitted to very tight tolerances (few tenths of millimeters) over the magnet’s length (more than 15 meters). Different parts of the cold mass have to be either measured or properly positioned throughout the assembly (see reference [1]), implying the use of a portable system. The measurement syste...
متن کاملInfluence of Geometrical Parameters on the Flexural Rigidity of the LHC Dipole Cold Mass Assembly
In order to predict the mechanical behavior of the LHC dipole cold mass in situations such as handling, transport and cool down, a number of important structural parameters are required. The dipole’s flexural rigidity determines entirely the mechanical elastic behavior of the cold mass. Therefore, models of a bent cold mass were created to calculate its rigidity. This paper presents a simplifie...
متن کاملGeometric and Magnetic Axes of the Lhc Dipole
The 15-m long superconducting dipoles of the Large Hadron Collider (LHC) with two-in-one design are curved by about 5 mrad to follow the beam trajectory. They are supported on three cold feet to minimise the vertical sagitta induced by their 35 tonnes weight. The cold masses contain at both ends local multipolar correctors to compensate for the detrimental effect of persistent current during in...
متن کاملX-Ray in-situ saturation monitoring, an aid to study relative permeability in water-wet carbonate rocks
The simultaneous flow of oil and water in porous media is described by relative permeability curves, mainly derived from laboratory experiments. Relative permeability is of paramount importance in predicting reservoir production performance and drive mechanisms and its value depends largely on the volume fraction of fluids present in the test samples. Nowadays X-ray scanners are one of the most...
متن کاملField-shape Imperfections of the Cern-lhc Dipole Arising from Mechanical Deformations and Component Tolerances
The stability of the geometry of the superconducting coils is essential to the field homogeneity of the LHC dipole magnets. Mechanical stresses during coil assembly, thermal stresses during cool-down and electromagnetic stresses during operation are the sources of deformations of the coil geometry. Additional sources of field-shape errors are the dimensional tolerances of the magnet components ...