Development of a Simplified, Cost Effective GC-ECD Methodology for the Sensitive Detection of Bromoform in the Troposphere
نویسندگان
چکیده
Wherever measurements have been made bromoform was found to be ubiquitous in the surface ocean in pmolar-nmolar concentrations. These measurements show concentrations in coastal regions orders of magnitude higher than in the pelagic oceans. Its atmospheric presence is primarily due to its release from algae and rapid transport to the marine boundary troposphere where it is known to participate in ozone chemistry via photochemical and catalytic pathways. Until quite recently, a limited number of studies existed (compared to other marine volatile organic compounds (VOCs)), mainly due to the analytical challenge(s) presented by the low environmental mixing ratios. In this work we detail the development of a simplified, cost effective method to detect and quantify bromoform in environmental air samples. Air samples (1.5 L) were preconcentrated onto a precooled adsorbent (Carbopack X/Carboxen 1016) trap. These samples were injected by means of rapid thermal desorption for separation and detection by GC-ECD. The system was calibrated by means of a custom-built permeation oven. A linear system response was achieved, having a detection limit of 0.73 ± 0.09 ppt. A range of environmental samples was analysed to demonstrate the ability of the technique to separate and identify bromoform from air samples. The results showed that bromoform concentrations typically averaged 24.7 ± 17.3 ppt in marine air samples, 68.5 ± 26.3 ppt in Cape Town urban air samples and 33.9 ± 40.5 ppt in simulated biomass burning plumes (SBBP).
منابع مشابه
Comparative Gas Chromatography of Halides Using Different Substituted Phenylboronic Acids as Derivatizing Reagents
The GC of halides (chloride, bromide and iodide) using phenylboronic acid (PBA), 4-bromophenylboronic acid (BPBA), 3, 5 bis (trifluoromethyl) phenylboronic acid (FPBA) and 2,4- dichlorophenylboronic acid (CPBA) as derivatizing reagents are compared. The reactions are carried out in the presence of mercuric salts. The detection systems used are FID and ECD. The thermal analysis of the compou...
متن کاملTheoretical Optimization of Troposphere Ionization Exchange Points to Reduce the Concentration of Fine Dust in Ahvaz City, Iran
Aims: The dust crisis and the numerous problems caused by it, which have affected most of the Western and Southwestern regions of Iran in recent years, need an appropriate and cost-effective solution to improve living and respiratory conditions without adverse human or environmental effects. The purpose of this study was to analyze the location of injection technology equipment to reduce the co...
متن کاملReproductive enhancement in buffalo: looking at urinary pheromones and hormones
The success of conception in buffalo is greatly dependent on precise estrus detection and time of artificial insemination (AI). Various visual, behavioral, biochemical and gyneco-clinical parameters have been tracked closely and a cost-effective combinatorial model has been developed to detect estrus in buffaloes. Pheromones play pivotal roles in reproduction and behavior of mammals. Urine, an ...
متن کاملDevelopment of Multiplex Reverse Transcription-Polymerase Chain Reaction for Simultaneous Detection of Influenza A, B and Adenoviruses
Background and objective:Millions of people in developing countries lose their lives due to acute respiratory infections, such as Influenza A & B and Adeno viruses. Given the importance of rapid identification of the virus, in this study the researchers attempted to design a method that enables detection of influenza A, B, and adenoviruses, quickly and simultaneously. ...
متن کاملThe Comparison of the Effectiveness of a Modified Conformation Sensitive Gel Electrophoresis with Denaturing High Performance Liquid Chromatography
Background: Several methods have been developed for detection of sequence variation in genes and each has its advantages and disadvantages. A disadvantage of them is that the simpler, cost-effective methods are commonly perceived as being less sensitive in their detection of sequence variation, whereas those with proven sensitivity have a requirement for complex or expensive laboratory equipmen...
متن کامل