A milestone in ribosomal crystallography: the construction of preliminary electron density maps at intermediate resolution.
نویسندگان
چکیده
Preliminary electron density maps of the large and the small ribosomal particles from halophilic and thermophilic sources, phased by the isomorphous replacement method, have been constructed at intermediate resolution. These maps contain features comparable in size with what is expected for the corresponding particles, and their packing arrangements are in accord with the schemes obtained by ab-initio procedures as well as with the motifs observed in thin sections of the crystals by electron microscopy. To phase higher resolution data, procedures are being developed for derivatization by specific labeling of the ribosomal particles at selected locations with rather small and dense clusters. Potential binding sites are being inserted either by site directed mutagenesis or by chemical modifications to facilitate cluster binding on the surface of the halophilic large and the thermophilic small ribosomal particles, which yield the crystals diffracting to highest resolution (2.9 and 7.3 A (1 A = 0.1 nm), respectively). For this purpose, the surface of these ribosomal particles is being characterized and procedures are being developed for quantitative detachment of selected ribosomal proteins and for their incorporation into core particles. The genes of these proteins are being cloned, sequenced, mutated to introduce reactive side groups, mainly cysteines, and overexpressed. In parallel, two in situ small and stable complexes were isolated from the halophilic ribosome. Procedures for their crystal production in large quantities are currently being developed. Models, reconstructed at low resolution from crystalline arrays of ribosomes and their large subunits, are being used for initial low-resolution phasing of the X-ray amplitudes. The interpretation of these models stimulated the design and the crystallization of complexes mimicking defined functional states of a higher quality than those obtained for isolated ribosomes. These models also inspired modelling experiments according to results of functional studies, performed elsewhere, focusing on the progression of nascent proteins.
منابع مشابه
Ribosomal crystallography: from crystal growth to initial phasing
Preliminary phases were determined by the application of the isomorphous replacement method at low and intermediate resolution for structure factor amplitudes collected from crystals of large and small ribosomal subunits from halophilic and thermophilic bacteria. Derivatization was performed with dense heavy atom clusters, either by soaking or by specific covalent binding prior to the crystalli...
متن کاملIdentification of secondary structure elements in intermediate-resolution density maps.
An increasing number of structural studies of large macromolecular complexes, both in X-ray crystallography and cryo-electron microscopy, have resulted in intermediate-resolution (5-10 A) density maps. Despite being limited in resolution, significant structural and functional information may be extractable from these maps. To aid in the analysis and annotation of these complexes, we have develo...
متن کاملEM-fold: De novo folding of alpha-helical proteins guided by intermediate-resolution electron microscopy density maps.
In medium-resolution (7-10 A) cryo-electron microscopy (cryo-EM) density maps, alpha helices can be identified as density rods whereas beta-strand or loop regions are not as easily discerned. We are proposing a computational protein structure prediction algorithm "EM-Fold" that resolves the density rod connectivity ambiguity by placing predicted alpha helices into the density rods and adding mi...
متن کاملMetal compounds as tools for the construction and the interpretation of medium-resolution maps of ribosomal particles.
Procedures were developed exploiting organometallic clusters and coordination compounds in combination with heavy metal salts for derivatization of ribosomal crystals. These enabled the construction of multiple isomorphous replacement (MIR) and multiple isomorphous replacement combined with anomalous scattering medium-resolution electron density maps for the ribosomal particles that yield the c...
متن کاملFitting atomic models into electron-microscopy maps.
Combining X-ray crystallographically determined atomic structures of component domains or subunits with cryo-electron microscopic three-dimensional images at around 22 A resolution can produce structural information that is accurate to about 2.2 A resolution. In an initial step, it is necessary to determine accurately the absolute scale and absolute hand of the cryo-electron microscopy map, the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biochemistry and cell biology = Biochimie et biologie cellulaire
دوره 73 11-12 شماره
صفحات -
تاریخ انتشار 1995