Error analysis of measured cerebral vascular response to acetazolamide stress by I-123-IMP autoradiographic method with single photon emission computed tomography: errors due to distribution volume of I-123-IMP.

نویسندگان

  • Hiroshi Ito
  • Kentaro Inoue
  • Ryoi Goto
  • Shigeo Kinomura
  • Tachio Sato
  • Tomohiro Kaneta
  • Kazunori Sato
  • Hiroshi Fukuda
چکیده

OBJECTIVES Iodine-123 (123I)-labeled N-isopropyl-p-iodoamphetamine (IMP) has been used as a cerebral blood flow (CBF) tracer for single-photon emission computed tomography (SPECT), and measurements of the CBF response to acetazolamide stress by SPECT with IMP are widely used to assess cerebral vascular reserve. To quantitate CBF by means of SPECT with IMP, an autoradiographic (ARG) method has been developed and is widely used. In the ARG method, CBF is calculated from the brain counts of the SPECT scan with an assumed distribution volume value of IMP (Vd). However, differences between true Vd and assumed Vd results in errors in calculated CBF. In the present study, errors in the CBF response to acetazolamide stress as calculated by the ARG method were investigated. METHODS SPECT studies were performed on 12 patients with steno-occlusive lesions of the major cerebral artery. Two studies were performed on separate days. The first study was performed at rest (baseline), and the second during acetazolamide stress. SPECT scans were performed at 40 min (early scan) and 180 min (delayed scan) after intravenous injection of IMP. RESULTS Although a simulation study showed that errors in calculated changes in CBF in response to acetazolamide stress, which result from differences between the true Vd and the assumed Vd, were larger when the baseline CBF and change in CBF were larger, values calculated by the ARG method with an assumed Vd were in good agreement with those calculated with true Vd obtained from early and delayed scan data. CONCLUSION These data indicate that errors in the calculated CBF response to acetazolamide stress as calculated by the ARG method are negligible even at high CBF responses. The ARG method is therefore reliable for measurement of CBF response to acetazolamide stress.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of tissue heterogeneity on cerebral vascular response to acetazolamide stress measured by an I-123-IMP autoradiographic method with single-photon emission computed tomography.

OBJECTIVES Single-photon emission computed tomography (SPECT) with iodine-123 (123I)-labeled N-isopropyl-p-iodoamphetamine (IMP) is widely used in measuring the cerebral blood flow (CBF) response to acetazolamide stress for assessment of cerebral vascular reserve. To quantitate CBF by means of SPECT with IMP, an autoradiographic (ARG) method has been developed and is widely used. Because the re...

متن کامل

Evaluation of crossed cerebellar diaschisis in 30 patients with major cerebral artery occlusion by means of quantitative I-123 IMP SPECT.

Quantitative crossed cerebellar diaschisis (CCD) and the correlation with a reduction in supratentorial regional cerebral blood flow (rCBF) and cerebrovascular reserve capacity (CVR) were investigated in clinically stable patients with major cerebral artery occlusion by the iodine-123-N-isopropyl-p-iodoamphetamine (I-123 IMP) single photon emission computed tomography (SPECT) method. Thirty pat...

متن کامل

Quantitative measurement of regional cerebral blood flow with flow-sensitive alternating inversion recovery imaging: comparison with [iodine 123]-iodoamphetamin single photon emission CT.

BACKGROUND AND PURPOSE Flow-sensitive alternating inversion recovery (FAIR) MR imaging is a technique for depicting cerebral perfusion without contrast enhancement. Our purpose was to determine whether quantification at FAIR imaging can be used to assess regional cerebral blood flow (rCBF) in a manner similar to [iodine 123]-iodoamphetamin ((123)I-IMP) single photon emission CT (SPECT). METHO...

متن کامل

A simple non-invasive I-123-IMP autoradiography method developed by modifying the simple non-invasive I-123-IMP microsphere method

Objective: We developed a simple non-invasive I-123-N-isopropyl-p-iodoamphetamine (123I-IMP) quantification method by analyzing chest RI-angiography and single photon emission computed tomography (SPECT) images based on the microsphere model (SIMS method). Theoretically, the SIMS method could be changed to the simple non-invasive ARG (SIARG) method by modifying the integrated washout ratio (WR)...

متن کامل

Quantitative measurement of regional cerebrovascular reactivity to acetazolamide using 123I-N-isopropyl-p-iodoamphetamine autoradiography with SPECT: validation study using H2 15O with PET.

UNLABELLED A simplified technique using (123)I-N-isopropyl-p-iodoamphetamine ((123)I-IMP) autoradiography (ARG) with SPECT has been proposed recently for quantifying regional cerebral blood flow (rCBF). To validate the accuracy of (123)I-IMP-ARG for quantifying regional cerebrovascular reactivity (rCVR) to acetazolamide, we compared rCVR determined using (123)I-IMP-ARG with that determined usin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of nuclear medicine

دوره 18 3  شماره 

صفحات  -

تاریخ انتشار 2004