Comparison between the SAPIEN S3 and the SAPIEN XT transcatheter heart valves: A single-center experience

نویسندگان

  • Fadi J Sawaya
  • Marco Spaziano
  • Thierry Lefèvre
  • Andrew Roy
  • Phillippe Garot
  • Thomas Hovasse
  • Antoinette Neylon
  • Hakim Benamer
  • Mauro Romano
  • Thierry Unterseeh
  • Marie-Claude Morice
  • Bernard Chevalier
چکیده

AIM To investigate the clinical outcomes of transcatheter aortic valve implantation (TAVI) with the SAPIEN 3 transcatheter heart valve (S3-THV) vs the SAPIEN XT valve (XT-THV). METHODS We retrospectively analyzed 507 patients that underwent TAVI with the XT-THV and 283 patients that received the S3-THV at our institution between March 2010 and December 2015. RESULTS Thirty-day mortality (3.5% vs 8.7%; OR = 0.44, P = 0.21) and 1-year mortality (25.7% vs 20.1%, P = 0.55) were similar in the S3-THV and the XT-THV groups. The rates of both major vascular complication and paravalvular regurgitation (PVR) > 1 were almost 4 times lower in the S3-THV group than the XT-THV group (major vascular complication: 2.8% vs 9.9%, P < 0.0001; PVR > 1: 2.4% vs 9.7%, P < 0.0001). However, the rate of new pacemaker implantation was almost twice as high in the S3-THV group (17.3% vs 9.8%, P = 0.03). In the S3 group, independent predictors of new permanent pacemaker were pre-procedural RBBB (OR = 4.9; P = 0.001), pre-procedural PR duration (OR = 1.14, P = 0.05) and device lack of coaxiality (OR = 1.13; P = 0.05) during deployment. CONCLUSION The S3-THV is associated to lower rates of major vascular complications and PVR but higher rates of new pacemaker compared to the XT-THV. Sub-optimal visualization of the S3-THV in relation to the aortic valvular complex during deployment is a predictor of new permanent pacemaker.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Procedural Results and Clinical Outcomes of Transcatheter Aortic Valve Implantation in Switzerland: An Observational Cohort Study of Sapien 3 Versus Sapien XT Transcatheter Heart Valves.

BACKGROUND New generation transcatheter heart valves (THV) may improve clinical outcomes of transcatheter aortic valve implantation. METHODS AND RESULTS In a nationwide, prospective, multicenter cohort study (Swiss Transcatheter Aortic Valve Implantation Registry, NCT01368250), outcomes of consecutive transfemoral transcatheter aortic valve implantation patients treated with the Sapien 3 THV ...

متن کامل

Comparison of SAPIEN 3 and SAPIEN XT transcatheter heart valve stent-frame expansion: evaluation using multi-slice computed tomography

AIMS Stent-frame morphology of the newer-generation, balloon-expandable transcatheter heart valve (THV), the SAPIEN 3 (S3), after transcatheter aortic valve implantation (TAVI) is unknown. We evaluated the THV stent-frame morphology post TAVI of the S3 using multi-slice computed tomography (MSCT) compared with the prior-generation THV, SAPIEN XT (S-XT). METHODS AND RESULTS A total of 94 conse...

متن کامل

Comparison of acute elastic recoil between the SAPIEN-XT and SAPIEN valves in transfemoral-transcatheter aortic valve replacement.

BACKGROUND The SAPIEN-XT is a newer generation balloon-expandable valve created of cobalt chromium frame, as opposed to the stainless steel frame used in the older generation SAPIEN valve. We sought to determine if there was difference in acute recoil between the two valves. METHODS All patients who underwent transfemoral-transcatheter aortic valve replacement using the SAPIEN-XT valve at the...

متن کامل

Changes in the Pacemaker Rate After Transition From Edwards SAPIEN XT to€SAPIEN 3 Transcatheter Aortic Valve€Implantation

METHODS The first 206 patients treated with the S3 were compared with 371 preceding patients treated with SAPIEN XT valves. Patients who previously underwent pacemaker or implantable cardioverter defibrillator implantation or transapical and valve-in-valve procedureswere excluded from the analysis. All patientsweremonitored for at least 7 days. Previous and new conduction abnormalities were doc...

متن کامل

Overexpansion of the SAPIEN 3 Transcatheter Heart Valve: A Feasibility Study.

Computed tomography (CT) images with cross-sectional areas of overex Lifesciences), 23-, 26-, and a 29-mm SAPIEN 3 transcatheter heart valv several new features designed to address the limitations of earlier generation devices. An initial feasibility study performed in Europe and Canada using the SAPIEN 3 demonstrated excellent early outcomes with a 30-day mortality rate of 2.1%, a stroke rate ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2016