Can tibial coverage in total knee replacement be reliably evaluated with three-dimensional image-based digital templating?

نویسندگان

  • A. J. Costa
  • S. Lustig
  • C. J. Scholes
  • J-C. Balestro
  • M. Fatima
  • D. A. Parker
چکیده

OBJECTIVES There remains a lack of data on the reliability of methods to estimate tibial coverage achieved during total knee replacement. In order to address this gap, the intra- and interobserver reliability of a three-dimensional (3D) digital templating method was assessed with one symmetric and one asymmetric prosthesis design. METHODS A total of 120 template procedures were performed according to specific rotational and over-hang criteria by three observers at time zero and again two weeks later. Total and sub-region coverage were calculated and the reliability of the templating and measurement method was evaluated. RESULTS Excellent intra- and interobserver reliability was observed for total coverage, when minimal component overhang (intraclass correlation coefficient (ICC) = 0.87) or no component overhang (ICC = 0.92) was permitted, regardless of rotational restrictions. CONCLUSIONS Measurement of tibial coverage can be reliable using the templating method described even if the rotational axis selected still has a minor influence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The reliability and accuracy of digital templating in total knee replacement.

We aimed to determine the reliability, accuracy and the clinical role of digital templating in the pre-operative work-up for total knee replacement. Initially a sample of ten pre-operative digital radiographs were templated by four independent observers to determine the inter- and intra-observer reliability of the process. Digital templating was then performed on the radiographs of 40 consecuti...

متن کامل

Three-dimensional analysis of the tibial resection plane relative to the arthritic tibial plateau in total knee arthroplasty

BACKGROUND Kinematically aligned total knee arthroplasty strives to correct the arthritic deformity by restoring the native tibial joint line. However, the precision of such surgical correction needs to be quantified in order to reduce recuts of the resection and to design assisting instrumentation. This study describes a method for novel three-dimensional analysis of tibial resection parameter...

متن کامل

Magnification error of digital x rays on the computer screen.

Templating x-rays of total hip and knee replacements pre-operatively are important to plan surgery. This is usually done using acetate templates of the prosthesis on hard copies of the x-ray. With the change in practice, to use digital x-rays on computer screens instead of hard copies, it is important to assess if acetate templates can be used for digital x-rays on the computer screen. This is ...

متن کامل

Quality Assessment of Turfgrasses Using NTEP Method Compared to an Image-Based Scoring System

The current methods of turfgrass evaluations are often based on human-based assessment methods. However, eliminating subjective errors from such evaluations is often impossible. This research compared the accuracy of human-based and digital image processing-based methods for quality assessment of turfgrasses. Four turfgrass plots were evaluated using the two mentioned methods. In the human-base...

متن کامل

Quality Assessment of Turfgrasses Using NTEP Method Compared to an Image-Based Scoring System

The current methods of turfgrass evaluations are often based on human-based assessment methods. However, eliminating subjective errors from such evaluations is often impossible. This research compared the accuracy of human-based and digital image processing-based methods for quality assessment of turfgrasses. Four turfgrass plots were evaluated using the two mentioned methods. In the human-base...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2013