Evaluation of the ability of primary selective enrichment to resuscitate heat-injured and freeze-injured Listeria monocytogenes cells.
نویسندگان
چکیده
Resuscitation rates of injured Listeria monocytogenes on conventional selective Listeria enrichment broth and nonselective Trypticase soy broth containing 0.6% yeast extract were compared. Cells were heated to 60 degrees C for 5 min or frozen at -20 degrees C for 7 days. Inoculation of Trypticase soy broth-yeast extract with the stressed cells resulted in growth that was superior to that in Listeria enrichment broth. Injured cells were fully recovered at 6 to 8 h.
منابع مشابه
Evaluation of a multiplex selective enrichment broth SEL for simultaneous detection of injured Salmonella, Escherichia coli O157:H7 and Listeria monocytogenes
Although many rapid and high throughput molecular methods have been developed in the recent years for the multiplex detection of foodborne pathogens, the simultaneous recovery and enrichment of sublethally injured cells is still a problem that needs to be considered. Combined with previous established multiplex real-time PCR assay, the capability of simultaneous recovery and enrichment of suble...
متن کاملEvaluation of selective direct plating media for their suitability to recover uninjured, heat-injured, and freeze-injured Listeria monocytogenes from foods.
Six direct plating media were evaluated for their suitability to recover uninjured, heat-injured, and freeze-injured cells of four strains of Listeria monocytogenes from four foods. Cells were inoculated into foods to achieve ca. 10(2) to 10(3), 10(4) to 10(5), or 10(5) to 10(6) viable cells per ml or g (low, medium, and high populations, respectively). No appreciable differences in recovery of...
متن کاملProfiling of recovery efficiencies for three standard protocols (FDA-BAM, ISO-11290, and modified USDA) on temperature-injured Listeria monocytogenes.
There have been a number of studies conducted in order to compare the efficiencies of recovery rates, utilizing different protocols, for the isolation of L. monocytogenes. However, the severity of multiple cell injury has not been included in these studies. In the current study, L. monocytogenes ATCC 19112 was injured by exposure to extreme temperatures (60°C and -20°C) for a one-step injury, a...
متن کاملEvaluation of Reverse Transcriptase 5' Nuclease Polymerase Chain Reaction assay for the Detection of Viable Heat-Injured and Resuscitated Listeria monocytogenes in Ground Pork
An anaerobic resuscitation-enrichment system was combined with a 5' nuclease reverse transcriptase (RT) protocol for detecting Listeria monocytogenes Scott A from artificially inoculated ground pork. When irradiation-sterilized ground pork containing L. monocytogenes (~6 x 10 5 CFU/g) was heated (60 o C, 14 min), 100% of the cells were injured, as indicated by no growth on selective Modified Ox...
متن کاملA novel strictly anaerobic recovery and enrichment system incorporating lithium for detection of heat-injured Listeria monocytogenes in pasteurized milk containing background microflora.
Heat-injured cells of Listeria monocytogenes were recovered from heated raw milk containing noninjured Enterococcus faecium by combining a simple method for obtaining strict anaerobiosis with a novel enrichment broth, Penn State University broth (PSU broth). Strictly anaerobic conditions were rapidly achieved by adding 0.5 g of filter-sterilized cysteine per liter to PSU broth and then purging ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied and environmental microbiology
دوره 58 9 شماره
صفحات -
تاریخ انتشار 1992