Quantification of chemiluminescent signals using photon-sensitive films or a CCD camera.
نویسندگان
چکیده
منابع مشابه
Improved Western blot detection using CCD digital imaging: Comparison of cooled-CCD digital imaging versus X-ray film
Chemiluminescent Western blotting is a popular protein detection method for studying proteins. The typical protocol for measuring chemiluminescent signal exposes the Western blot to laboratory-grade X-ray film, but digital imaging using a cooled-CCD camera is proving to be a more functional choice for researchers. The Thermo Scientific MYECL Imager offers digital imaging with a number of improv...
متن کاملIncorporation of biotinylated nucleotides for the quantification of PCR-amplified HIV-1 DNA by chemiluminescence.
Chemiluminescent detection of polymerase chain reaction (PCR-)amplified DNA was used as a quantitative method for detecting HIV-1. For this purpose, biotinylated dUMP was directly incorporated into the amplified DNA during the PCR reaction. Biotinylation was visualized in an enzymatic reaction using avidine-conjugated alkaline phosphatase and its chemiluminescent 1,2-dioxetane substrate AMPPD, ...
متن کاملUsing a CCD camera imaging system as a recording device to quantify human DNA by slot blot hybridization.
Slot blot hybridization of membrane-immobilized, single-stranded human DNA with the higher primate-specific alphoid probe D17Z1 is routinely used in forensic science to estimate the amount of DNA in biological samples. Typically, a chemiluminescent signal captured on film records the hybridization, and the quantity of the signal is related to the amount of immobilized DNA. Digital imaging using...
متن کاملThe perceptibility curve test applied to CCD and two methods of digitization of dental film-based radiographs
Objectives: Several methods of image acquisition are accessible in dentistry. There is no overall acceptable method for image digitization so all different types of images can be comparable. The objective of this study was to compare the diagnostic accuracy of different methods of image digitization. Methods: This accuracy diagnostic test study used perceptibility curve test which first intr...
متن کاملDetermination of Optimum Planar Imaging Parameters for Small Structures with Diameters Less Than the Resolution of the Gamma Camera
Introduction: The limited spatial resolution of the gamma camera hinders the absolute quantification of planar images of small structures. The imaged structures are affected by partial volume effects (PVEs), which can spread activity and lead to underestimation of the regional distribution. The use of optimum planar parameters reduces the impact of the limited spatial resolution of the gamma c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- BioTechniques
دوره 35 2 شماره
صفحات -
تاریخ انتشار 2003