Influence of automated disc margin determination on Stratus OCT optic nerve head measurements
نویسندگان
چکیده
PURPOSE To analyze the influence of manual correction of the automatically determined edge of the optic nerve head (ONH) in optic disc measurements in cases in which the optical coherence tomography did not identify the disc limits correctly. METHODS The study included 127 eyes from 127 consecutive patients with glaucoma, suspects, and healthy individuals. In a retrospective analysis, eyes that underwent testing with the Stratus OCT (software version 4.0, Carl Zeiss Meditec, Dublin, CA, USA) Fast Optic Disc protocol were evaluated. Forty-seven eyes in which either the manual assignment was not necessary or the signal strength was below six were excluded. After image acquisition and processing, one expert examiner manually corrected the determination of the edge of the ONH, identified as the end of the retinal pigment epithelium/choriocapillaris complex. Disc area, cup area, rim area, and cup/disc area ratio results were compared before and after the optic disc margin manually corrected determination. Paired t-test was performed to evaluate the differences, and Bland-Altman plots were used to display the relationships between measurements. RESULTS Eighty eyes from 80 individuals were included in the analyses. No statistically signifiant difference (P=.538) was found when analyzing results obtained with automated and manual determination of rim area (mean ± standard deviation; 1.30±0.45 mm(2) and 1.29±0.39 mm(2), respectively). Cup area (1.39±0.58 mm(2) and 1.31±0.55 mm(2), respectively), cup/disc area ratio (0.50±0.16 mm(2) and 0.49±0.15 mm(2), respectively), and disc area results (2.69±0.55 mm(2) and 2.60±0.51 mm(2), respectively) were significantly different. CONCLUSION The Stratus OCT ONH Report results were little influenced when optic disc limits were manually determined. Therefore the standard automated Stratus OCT disc margin assignment is adequate, and manual correction is not necessary.
منابع مشابه
Comparison of optic nerve head parameter measurements obtained by time-domain and spectral-domain optical coherence tomography.
PURPOSE To compare the measurements of the optic nerve head (ONH) parameters provided by time-domain (TD) and spectral-domain (SD) optical coherence tomography (OCT). METHODS Four ONH parameters were analyzed: optic disc area, rim area, cup-to-disc area ratio (CDR), and vertical cup-to-disc ratio (VCDR). Stratus OCT and Cirrus HD-OCT were used to obtain measurements by TD-OCT and SD-OCT, resp...
متن کاملEXTENDED REPORT Correlation between retinal nerve fibre layer thickness and optic nerve head size: an optical coherence tomography study
Aim: To investigate the correlation between retinal nerve fibre layer (RNFL) thickness and optic nerve head (ONH) size in normal white subjects by means of optical coherence tomography (OCT). Methods: 54 eyes of 54 healthy subjects aged between 15 and 54 underwent peripapillary RNFL thickness measurement by a series of three circular scans with a 3.4 mm diameter (Stratus OCT, RNFL Thickness 3.4...
متن کاملCorrelation between retinal nerve fibre layer thickness and optic nerve head size: an optical coherence tomography study.
AIM To investigate the correlation between retinal nerve fibre layer (RNFL) thickness and optic nerve head (ONH) size in normal white subjects by means of optical coherence tomography (OCT). METHODS 54 eyes of 54 healthy subjects aged between 15 and 54 underwent peripapillary RNFL thickness measurement by a series of three circular scans with a 3.4 mm diameter (Stratus OCT, RNFL Thickness 3.4...
متن کاملDetection of glaucoma progression with stratus OCT retinal nerve fiber layer, optic nerve head, and macular thickness measurements.
PURPOSE To evaluate and compare the ability of optical coherence tomography (OCT) retinal nerve fiber layer (RNFL), optic nerve head, and macular thickness parameters to detect progressive structural damage in glaucoma. METHODS This observational cohort study included 253 eyes of 253 patients. Images were obtained annually with the Stratus OCT (Carl Zeiss Meditec, Inc., Dublin, CA) along with...
متن کاملOptic Nerve Head Measurements With Optical Coherence Tomography: A Phantom-Based Study Reveals Differences Among Clinical Devices
PURPOSE Optical coherence tomography (OCT) can monitor for glaucoma by measuring dimensions of the optic nerve head (ONH) cup and disc. Multiple clinical studies have shown that different OCT devices yield different estimates of retinal dimensions. We developed phantoms mimicking ONH morphology as a new way to compare ONH measurements from different clinical OCT devices. METHODS Three phantom...
متن کامل