Ultrasensitive Detection of Ferulic Acid Using Poly(diallyldimethylammonium chloride) Functionalized Graphene-Based Electrochemical Sensor
نویسندگان
چکیده
The electrochemical redox of ferulic acid (FA) was investigated systematically by cyclic voltammetry (CV) with a poly(diallyldimethylammonium chloride) functionalized graphene-modified glassy carbon electrode (PDDA-G/GCE) as a working electrode. A simple and sensitive differential pulse voltammetry (DPV) technique was proposed for the direct quantitative determination of FA in Angelica sinensis and spiked human urine samples for the first time. The dependence of the intensities of currents and potentials on nature of the supporting electrolyte, pH, scan rate, and concentration was investigated. Under optimal conditions, the proposed sensor exhibited excellent electrochemical sensitivity to FA, and the oxidation peak current was proportional to FA concentration in the range of 8.95 × 10(-8) M ~5.29 × 10(-5) M, with a relatively low detection limit of 4.42 × 10(-8) M. This fabricated sensor also displayed acceptable reproducibility, long-term stability, and high selectivity with negligible interferences from common interfering species. Besides, it was applied to detect FA in Angelica sinensis and biological samples with satisfactory results, making it a potential alternative tool for the quantitative detection of FA in pharmaceutical analysis.
منابع مشابه
Electrophoretic separation of chlorophenols on silica nanospheres-coated poly(dimethylsiloxane) microchip using a Nafion/graphene-modified carbon electrode for detection.
In the present work, the micellar electrophoretic separation of five chlorophenols (CPs) on a functionalized poly(dimethylsiloxane) (PDMS) microchip with amperometric detection was performed. In order to achieve high resolution by controlling the electroosmotic flow (EOF) as well as signal detection by suppressing analytes adsorption, the microchannel was functionalized by poly(diallyldimethyla...
متن کاملSensitive Electrochemical Capsaicin Sensor Based on a Screen Printed Electrode Modified with Poly(sodium 4-styrenesulfonate) Functionalized Graphite.
A sensitive capsaicin sensor was constructed based on a poly(sodium 4-styrenesulfonate) functionalized graphite modified screen printed electrode (PSS-Grp/SPE) in this study. The PSS-Grp and poly(diallyldimethylammonium chloride) functionalized graphite (PDDA-Grp) were easily synthesized by interacting Grp with PSS and PDDA through sonication, and resulted in negative and with positive charges ...
متن کاملAn Electrochemical Sensor Based on Nickel Oxides Nanoparticle/ Graphene Composites for Electrochemical Detection of Epinephrine
The combination of graphene and nickel oxide nanoparticles yields nanostructured electrochemical sensor formed a novel kind of structurally uniform and electrocatalytic activity material. In cyclic voltammetry studies, in the presence of epinephrine, nickel oxide / graphene composite modified electrode shows a significantly higher current response for epinephrine oxidation. Based on differenti...
متن کاملVoltammetric determination of acetaminophen and tryptophan using a graphite screen printed electrode modified with functionalized graphene oxide nanosheets within a Fe3O4@SiO2 nanocomposite
A high sensitive electrochemical nanostructure sensor based on graphene oxide/Fe3O4@SiO2 nanocomposite modified graphite screen printed electrode (GO/Fe3O4@SiO2/SPE) has been developed for trace analysis of acetaminophen. The electrochemical study of the modified electrode, as well as its efficiency for simultaneous voltammetric oxidation of acetaminophen and tryptophan is described. Compared w...
متن کاملFabrication of Gold Nanoparticles/Graphene-PDDA Nanohybrids for Bio-detection by SERS Nanotechnology
In this research, graphene nanosheets were functionalized with cationic poly (diallyldimethylammonium chloride) (PDDA) and citrate-capped gold nanoparticles (AuNPs) for surface-enhanced Raman scattering (SERS) bio-detection application. AuNPs were synthesized by the traditional citrate thermal reduction method and then adsorbed onto graphene-PDDA nanohybrid sheets with electrostatic interaction...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2014 شماره
صفحات -
تاریخ انتشار 2014