Investigating the Capability to Resolve Complex White Matter Structures with High b-Value Diffusion Magnetic Resonance Imaging on the MGH-USC Connectom Scanner
نویسندگان
چکیده
One of the major goals of the NIH Blueprint Human Connectome Project was to map and quantify the white matter connections in the brain using diffusion tractography. Given the prevalence of complex white matter structures, the capability of resolving local white matter geometries with multiple crossings in the diffusion magnetic resonance imaging (dMRI) data is critical. Increasing b-value has been suggested for delineation of the finer details of the orientation distribution function (ODF). Although increased gradient strength and duration increase sensitivity to highly restricted intra-axonal water, gradient strength limitations require longer echo times (TE) to accommodate the increased diffusion encoding times needed to achieve a higher b-value, exponentially lowering the signal-to-noise ratio of the acquisition. To mitigate this effect, the MGH-USC Connectom scanner was built with 300 mT/m gradients, which can significantly reduce the TE of high b-value diffusion imaging. Here we report comparisons performed across b-values based on q-ball ODF metrics to investigate whether high b-value diffusion imaging on the Connectom scanner can improve resolving complex white matter structures. The q-ball ODF features became sharper as the b-value increased, with increased power fraction in higher order spherical harmonic series of the ODF and increased peak heights relative to the overall size of the ODF. Crossing structures were detected in an increasingly larger fraction of white matter voxels and the spatial distribution of two-way and three-way crossing structures was largely consistent with known anatomy. Results indicate that dMRI with high diffusion encoding on the Connectom system is a promising tool to better characterize, and ultimately understand, the underlying structural organization and motifs in the human brain.
منابع مشابه
Signal Intensity of High B-value Diffusion-weighted Imaging for the Detection of Prostate Cancer
Background: Diffusion-weighted imaging (DWI) is a main component of multiparametric MRI for prostate cancer detection. Recently, high b value DWI has gained more attention because of its capability for tumor characterization. Objective: To assess based on histopathological findings of transrectal ultrasound (TRUS)-guided prostate biopsy as a reference, an...
متن کاملClinical Significance of Diffusion Weighted Magnetic Resonance Imaging on Treatment Efficacy in MS Patients With Acute Attacks
Background: Despite the existence of various imaging methods, the accurate diagnosis of many neurodegenerative diseases is still controversial. The use of advanced imaging techniques, such as the diffusion weighted imaging can be help the early detection of MS and evaluation of the treatment efficacy in these patients. Materials and method: 24 MS patients with acute attack and thirty healthy s...
متن کاملHigh angular resolution diffusion imaging reveals intravoxel white matter fiber heterogeneity.
Magnetic resonance (MR) diffusion tensor imaging (DTI) can resolve the white matter fiber orientation within a voxel provided that the fibers are strongly aligned. However, a given voxel may contain a distribution of fiber orientations due to, for example, intravoxel fiber crossing. The present study sought to test whether a geodesic, high b-value diffusion gradient sampling scheme could resolv...
متن کاملPGSE, OGSE, and sensitivity to axon diameter in diffusion MRI: Insight from a simulation study
PURPOSE To identify optimal pulsed gradient spin-echo (PGSE) and oscillating gradient spin-echo (OGSE) sequence settings for maximizing sensitivity to axon diameter in idealized and practical conditions. METHODS Simulations on a simple two-compartment white matter model (with nonpermeable cylinders) are used to investigate a wide space of clinically plausible PGSE and OGSE sequence parameters...
متن کامل"Squashing peanuts and smashing pumpkins": how noise distorts diffusion-weighted MR data.
New diffusion-weighted imaging (DWI) methods, including high-b, q-space, and high angular resolution MRI methods, attempt to extract information about non-Gaussian diffusion in tissue that is not provided by low-b-value (b approximately 1000 s mm(-2)) diffusion or diffusion tensor magnetic resonance imaging (DT-MRI). Additionally, DWI data with higher spatial resolution are being acquired to re...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Brain connectivity
دوره 4 9 شماره
صفحات -
تاریخ انتشار 2014