The Predictive Value of Pulse Oximeters for Pulse Improvement after Angiography in Infants and Children
نویسندگان
چکیده
BACKGROUND Information from pulse oximeter waves confirms the presence of a pulse and helps obtain waves from tissue when the supplying artery is not readily accessible. OBJECTIVES This study determined the predictive value of pulse oximeters for detecting improved arterial pulses after angiography. PATIENTS AND METHODS This cross-sectional, multi-center study included 467 4-day-old to 12-year-old patients and was conducted from January 2012 to January 2016. Angiographies were performed on 12-year-old or younger children for various medical reasons using venous, arterial, or both types of paths. The posterior malleolar or dorsalis pedis were palpated in punctured lower extremities. In the absence of a pulse, pulse oximetry was performed to identify pulse curves at 1 hour, 6 hours, and 12 hours after each angiography. RESULTS Pulse oximetry displayed the pulses of 319 patients immediately following each angiography. Of these, 262 patients had palpable pulses at 6 hours after angiography (P < 0.0001), while 57 patients had no palpable pulse. Of these 57 patients, 15 had no palpable pulse at 12 hours after angiography (P < 0.0001). The odds of pulse improvement in children 6 hours after catheter angiography were 76% for the arterial path, 90% for the venous path, and 83.2% for both paths. At 12 hours after catheter angiography, these values increased to 91.6% for the arterial path, 100% for the venous path, and 95.9% for both paths. CONCLUSIONS The pulse oximeter can display the pulse curve immediately (1 hour) after angiography and indicate pulse improvement at 12 hours maximally following an angiography. In this case, heparin alone may be used instead of thrombolytic agents.
منابع مشابه
بررسی مقایسهای تأثیر دو روش آرامسازی بنسون و پیش دارو بر روی تعداد تنفس و ضربان نبض در بیماران تحت آنژیوگرافی عروق کرونر
Background & Aim: One of the cause of anxiety for most patients is hospitalization. Once the patients are hospitalized for cardiac catheterization, the anxiety would be augmented. The anxiety raises body physiological and psychological activities such as: heart rate and respiratory rate. This research, as clinical trial study, has the objective to determine the influence of applying two methods...
متن کاملPerformance Evaluation of New-Generation Pulse Oximeters in the NICU: Observational Study.
This crossover observational study compares the data characteristics and performance of new-generation Nellcor OXIMAX and Masimo SET SmartPod pulse oximeter technologies. The study was conducted independent of either original equipment manufacturer (OEM) across eleven preterm infants in a Neonatal Intensive Care Unit (NICU). The SmartPods were integrated with Dräger Infinity Delta monitors. The...
متن کاملComparative Study of Pulp Vitality in Primary and Young Permanent Molars in Human Children with Pulse Oximeter and Electric Pulp Tester
AIM AND OBJECTIVE The purpose of this study was to compare the pulp testing methods (pulse oximetry and electric pulp test) in primary and young permanent teeth of children. MATERIALS AND METHODS The study included a total of 155 children aged 4 to 15 years. Twenty children formed control group I. Study group included all healthy, 85 primary 2nd molars in group II and 85 permanent 1st molars ...
متن کامل"New-generation" pulse oximeters in extremely low-birth-weight infants: how do they perform in clinical practice?
The aim of this study was to evaluate the performance of "new-generation" pulse oximeters in extremely low-birth-weight ([ELBW] ≤ 1000 g) infants. In a prospective crossover observational study, the performance of pulse oximeters of 3 brands (Masimo, Nellcor, and Philips) was evaluated by dual SpO2 measurement in ELBW infants. Disposable probes of either equal or different brands were placed ar...
متن کاملAssessing high-risk infants in the delivery room with pulse oximetry.
Heart rate and oxygenation status are essential to the delivery room assessment of newborn infants. Pulse oximetry (PO) can capture these two variables but low peripheral perfusion, patient motion and the presence of ambient lighting can challenge the technology. New generation pulse oximeters claim to measure through these conditions. The objective of this study was to assess the performance o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 26 شماره
صفحات -
تاریخ انتشار 2016