Efficiency at different interaction depths in large coplanar CdZnTe detectors

نویسنده

  • Z. He
چکیده

This paper presents some studies performed with a state of the art large volume, 1.5 cm diameter 1.0 cm thick, cylindrical CdZnTe coplanar detector with a new anode pattern design in the line of units previously reported. The absolute efficiency of the detector for different interaction depths is quantified. The detector’s ideal response is simulated with a Monte Carlo code and compared with experimental results. Some conclusions regarding interaction depth profiles, detector efficiency, the new anode pattern design and device quality are reported. These are further compared with the behavior of previous coplanar units. r 2004 Elsevier B.V. All rights reserved. PACS: 29.40.Wk; 72.80.Ey; 73.40.Rw; 73.40.Sx

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of multi-element CdZnTe detectors

Single-element CdZnTe detectors are limited in size, and therefore efficiency, by the poor hole transport, even with a coplanar grid. We are investigating the possibility of a 27-element (3 × 3 × 3) array using 15 mm × 15 mm × 15 mm elements for gamma-ray energies to 10 MeV for NASA planetary missions. We present experimental results for combinations of various size coplanar grid detectors usin...

متن کامل

Coplanar grid CdZnTe detectors for space science applications

The characteristics and performance for two of the latest coplanar grid CdZnTe detectors, which use the thirdgeneration coplanar grid design, will be discussed. These detectors, with dimensions of 1.5×1.5×0.9 cm and 1.5×1.5×0.95 cm, were fabricated by Baltic Scientific Instruments, Ltd., using crystals from Yinnel Tech, Inc. The high μeτe product measured for these crystals will lead to improve...

متن کامل

A Modeling Method to Calibrate the Interaction Depth in 3-D Position Sensitive CdZnTe Gamma-Ray Spectrometers

The gamma ray interaction depth in 3-D position scnsitive CdZnTe dctectors is currently determined by the pulse height ratio ofthe cathode signal to the anode pixel signal (CIA ratio). In expcriments with our 3-D CdZnTe dctectors, thc photopeak area as a fuuction of the CIA ratio deviates from the expected exponential attcnuation with depth. This indicatcs that the CIA ratio is not proportional...

متن کامل

Impact of drift time variation on the Compton image from large-volume CdZnTe crystals

In pixelated CdZnTe detectors, multiple interaction gamma-ray events are critical because they permit Compton imaging. However, in large-volume CdZnTe crystals, the depth of multiple interaction events is often poorly reconstructed due to significant nonuniformity of electron drift velocity while the depth of single interaction events can be accurately reconstructed using signal ratios. The non...

متن کامل

Direct Conversion CdZnTe and CdTe Detectors for Digital Mammography

Hybrid CdZnTe and CdTe pixel detector arrays with 50 50 micron pixel sizes that convert x-rays directly into charge signals are under development at NOVA for applications to digital mammography. CdZnTe and CdTe have superior x-ray quantum efficiency compared to either emulsion-based film, phosphor-based detectors or other low-Z, solid-state detectors such as silicon. In this paper, latest resul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004