Total body irradiation with a reconditioned cobalt teletherapy unit

نویسندگان

  • Michael D.C. Evans
  • Renée‐Xavière Larouche
  • Marina Olivares
  • Pierre Léger
  • Joe Larkin
  • Carolyn R. Freeman
  • Ervin B. Podgorsak
چکیده

While the current trend in radiotherapy is to replace cobalt teletherapy units with more versatile and technologically advanced linear accelerators, there remain some useful applications for older cobalt units. The expansion of our radiotherapy department involved the decommissioning of an isocentric cobalt teletherapy unit and the replacement of a column-mounted 4-MV LINAC that has been used for total body irradiation (TBI). To continue offering TBI treatments, we converted the decommissioned cobalt unit into a dedicated fixed-field total body irradiator and installed it in an existing medium-energy LINAC bunker. This article describes the logistical and dosimetric aspects of bringing a reconditioned cobalt teletherapy unit into clinical service as a total body irradiator.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of Indigenous Source of Cobalt Suitable for Radiation Technology Applications

The role of Cobalt-60 as a radiation source in teletherapy for the treatment of cancer needs hardly to be reiterated. Although not used commonly in developed countries, cobalt-60 teletherapy machines can still be regarded as a very viable and cost effective option for the treatment of a sizeable fraction of cancer patients. At present in India, there are only 399 teletherapy units (280 telecoba...

متن کامل

Patterns of patient specific dosimetry in total body irradiation.

PURPOSE Total body irradiation (TBI) has been used for bone marrow transplant for hematologic and immune deficiency conditions. The goal of TBI is to deliver a homogeneous dose to the entire body, with a generally accepted range of dose uniformity being within ± 10% of the prescribed dose. The moving table technique for TBI could make dose uniform in whole body by adjusting couch speed. However...

متن کامل

Quality control of blood irradiation with a teletherapy unit: damage to stored red blood cells after cobalt-60 gamma irradiation.

BACKGROUND Previous publications have documented the damage caused to red blood cells (RBCs) irradiated with X-rays produced by a linear accelerator and with gamma rays derived from a 137Cs source. The biologic effects on RBCs of gamma rays from a 60Co source, however, have not been characterized. STUDY DESIGN AND METHODS This study investigated the effect of 3000 and 4000 cGy on the in vitro...

متن کامل

Microscopical Analysis of Fractionated Cobalt-60 Radiotherapy Effects on Mandibles of Rats*

OBJECTIVE: The objective of the present study was to evaluate both immediate and late effects of fractionated cobalt-60 teletherapy over the mean percentage of empty osteocyte lacunae in rats mandibles. MATERIALS AND METHODS: The animals sampling (n = 45) was divided into three groups with 15 specimens each: group 1 – submitted to fractionated teletherapy (60 Gy) and sacrificed following the la...

متن کامل

Reduced incidence of interstitial pneumonitis after allogeneic hematopoietic stem cell transplantation using a modified technique of total body irradiation

Allogeneic hematopoietic stem cell transplantation is a curative-intent treatment for patients with high-risk hematologic diseases. However, interstitial pneumonitis (IP) and other toxicities remain major concerns after total body irradiation (TBI). We have proposed using linear accelerators with rice-bag compensators for intensity modulation (IM-TBI), as an alternative to the traditional cobal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2006