pHi and pHo at different depths in perfused myocardium measured by confocal fluorescence microscopy.
نویسندگان
چکیده
Confocal microscopy and the H+-sensitive fluorophore carboxyseminaphthorhodafluor-1 (SNARF-1) were used to measure either intracellular pH (pHi) or extracellular pH (pHo) in isolated, arterially perfused rabbit papillary muscles. Single-excitation, dual-emission fluorescent images of the endocardial surface and underlying myocardium to a depth of 300 μm were simultaneously recorded from perfused cylindrical muscles suspended in a controlled atmosphere oriented oblique to the focal plane. Contraction was inhibited by the addition of butanedione monoxime. In separate muscles, pHo was measured during continuous perfusion of SNARF-1 free acid. pHi measurements were made after the muscle was loaded with SNARF-1/AM and the extracellular space was cleared of residual fluorophore. Initial experiments demonstrated the uniformity of ratiometric measurements as a function of pH, image depth, and fluorophore concentration, thereby establishing the potential feasibility of this method for quantitative intramural pH measurements. In subsequent experiments, the method was validated in isolated, arterially perfused rabbit papillary muscle during normal arterial perfusion and as pHi and pHo were altered by applying CO2 externally, exchanging HEPES and bicarbonate buffers, and changing pHi with NH4Cl washout. We conclude that in situ confocal fluorescent microscopy can measure pHi and pHo changes at the endocardial surface and deeper endocardial layers in arterially perfused ventricular myocardium. This method has the potential to study pHi regulation in perfused myocardium at boundaries where diffusion of gases, metabolites, and peptides are expected to modify processes that regulate pHi.
منابع مشابه
The Effect of Extracellular pH Changes on Intracellular pH and Nitric Oxide Concentration in Endothelial and Smooth Muscle Cells from Rat Aorta
AIMS It has been known for more than a century that pH changes can alter vascular tone. However, there is no consensus about the effects of pH changes on vascular response. In this study, we investigated the effects of extracellular pH (pHo) changes on intracellular pH (pHi) and intracellular nitric oxide concentration ([NO]i) in freshly isolated endothelial cells and cross sections from rat ao...
متن کاملChanges in extracellular and intracellular pH in ischemic rabbit papillary muscle.
The extracellular pH (pHo) and intracellular pH (pHi) were simultaneously measured with H(+)-sensitive microelectrodes in the rabbit papillary muscle during normal arterial perfusion and no-flow ischemia. The preparation was kept in an artificial gaseous atmosphere (N2 and CO2 during ischemia) without a surrounding fluid layer. Cylindrical muscles of small diameters (less than 1.0 mm) were sele...
متن کاملAn evaluation of two-photon excitation versus confocal and digital deconvolution fluorescence microscopy imaging in Xenopus morphogenesis.
The ability to visualize cell motility occurring deep in the context of opaque tissues will allow many currently intractable issues in developmental biology and organogenesis to be addressed. In this study, we compare two-photon excitation with laser scanning confocal and conventional digital deconvolution fluorescence microscopy, using the same optical configuration, for their ability to resol...
متن کاملRegulation of intracellular pH in human neutrophils
The intracellular pH (pHi) of isolated human peripheral blood neutrophils was measured from the fluorescence of 6-carboxyfluorescein (6-CF) and from the equilibrium distribution of [14C]5,5-dimethyloxazolidine -2,4-dione (DMO). At an extracellular pH (pHo) of 7.40 in nominally CO2-free medium, the steady state pHi using either indicator was approximately 7.25. When pHo was suddenly raised from ...
متن کاملFluorescence microscopy three-dimensional depth variant point spread function interpolation using Zernike moments
In three-dimensional fluorescence microscopy the point spread function (PSF) changes with depth, inducing errors in the restored images when these variations are neglected during the deconvolution of thick specimens. Some deconvolution algorithms have been developed to take the depth variations of the PSF into consideration. For these algorithms, the accuracy of the estimated structures depends...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The American journal of physiology
دوره 275 6 Pt 2 شماره
صفحات -
تاریخ انتشار 1998