IsoBED: a tool for automatic calculation of biologically equivalent fractionation schedules in radiotherapy using IMRT with a simultaneous integrated boost (SIB) technique

نویسندگان

  • Vicente Bruzzaniti
  • Armando Abate
  • Massimo Pedrini
  • Marcello Benassi
  • Lidia Strigari
چکیده

BACKGROUND An advantage of the Intensity Modulated Radiotherapy (IMRT) technique is the feasibility to deliver different therapeutic dose levels to PTVs in a single treatment session using the Simultaneous Integrated Boost (SIB) technique. The paper aims to describe an automated tool to calculate the dose to be delivered with the SIB-IMRT technique in different anatomical regions that have the same Biological Equivalent Dose (BED), i.e. IsoBED, compared to the standard fractionation. METHODS Based on the Linear Quadratic Model (LQM), we developed software that allows treatment schedules, biologically equivalent to standard fractionations, to be calculated. The main radiobiological parameters from literature are included in a database inside the software, which can be updated according to the clinical experience of each Institute. In particular, the BED to each target volume will be computed based on the alpha/beta ratio, total dose and the dose per fraction (generally 2 Gy for a standard fractionation). Then, after selecting the reference target, i.e. the PTV that controls the fractionation, a new total dose and dose per fraction providing the same isoBED will be calculated for each target volume. RESULTS The IsoBED Software developed allows: 1) the calculation of new IsoBED treatment schedules derived from standard prescriptions and based on LQM, 2) the conversion of the dose-volume histograms (DVHs) for each Target and OAR to a nominal standard dose at 2Gy per fraction in order to be shown together with the DV-constraints from literature, based on the LQM and radiobiological parameters, and 3) the calculation of Tumor Control Probability (TCP) and Normal Tissue Complication Probability (NTCP) curve versus the prescribed dose to the reference target.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions

Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...

متن کامل

Simultaneous integrated boost-intensity-modulated radiotherapy in head and neck cancer.

OBJECTIVES/HYPOTHESIS To review toxicity and outcomes in patients with head and neck cancer treated with simultaneous integrated boost-intensity-modulated radiotherapy (SIB-IMRT). STUDY DESIGN Review of experience with the SIB-IMRT technique. METHODS Fifty patients were treated with the SIB-IMRT technique. Two possible schedules of radiation therapy (RT) were used: SIB 70 (70/60/54 in 33 fr...

متن کامل

Prostate IMRT fractionation strategies: two-phase treatment versus simultaneous integrated boost

The availability of inverse planning and intensity modulated radiotherapy (IMRT) technology opened the possibility of designing new treatment strategies with superior dose distributions, namely tighter treatment margins and therefore better organ sparing. Recently Mohan et al.,1 and Wu et al.,2 have suggested a »simultaneous integrated boost« (SIB) IMRT approach to head and neck Radiol Oncol 20...

متن کامل

Influence of simultaneous-integrated boost, intensity- modulated radiation therapy on electroencephalogram records: Case report­

60-year-old woman was treated for a brain metastasis. The patient received intensity-modulated radiation therapy (SIB-IMRT) dose of 30 Gy for the whole brain and 40 Gy delivered simultaneously to individual brain metastases in 10 fractions. The present report investigated the influence of applied novel prepared treatment plan, among others the fractionation protocol on the electroencephalogram ...

متن کامل

Intensity-modulated radiotherapy with integrated-boost in patients with bone metastasis of the spine: study protocol for a randomized controlled trial

BACKGROUND Stereotactic body radiation therapy (SBRT) using intensity-modulated radiotherapy (IMRT) with dose escalation by simultaneous integrated boost (SIB) can be a safe modality for treating spinal bone metastases with enhanced targeting accuracy and improve local tumor control. METHODS/DESIGN This is a single-center, prospective, randomized, controlled trial. One hundred and twenty pati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 30  شماره 

صفحات  -

تاریخ انتشار 2011