Locked volar plating for complex distal radius fractures: Patient reported outcomes and satisfaction
نویسندگان
چکیده
BACKGROUND Distal radius fractures are common. The increasing prevalence of osteoporosis contributes to frequently complex articular injuries sustained even after low energy falls. The best method of treating complex type C distal radius fractures is debated. Locked volar plating and external fixation are both widely used with good reported results. Measures of success are traditionally based on technical measurements or the perception of the surgeon. Patient reported measures of outcome are increasingly recognised as important markers of surgical success. We report our experience using locked volar plating for complex type C distal radius fractures as well as patient reported measures of success and satisfaction. METHODS Over a 12 month period we treated 21 patients with type C distal radius fractures using locked volar plating. These patients were followed up for at least 12 months and the outcome was assessed using clinical examination, grip strength measurements, radiographs and Patient Rated Wrist Evaluation (PRWE) scoring. RESULTS The 21 patients studied had an average age of 48 years. There were 8 men and 13 women. All of the fractures had united by 3 months. There were no cases of wound infection or tendon injury/irritation. Patients reported low pain scores, good patient rated wrist evaluation scores and high levels of satisfaction. CONCLUSIONS Locked volar plating for complex distal radius fractures produces good results when assessed using patient reported measures of outcome. Further work should address whether locked volar plating offers superior outcomes and patient satisfaction compared to external fixation.
منابع مشابه
Wrist function recovers more rapidly after volar locked plating than after external fixation but the outcomes are similar after 1 year
BACKGROUND AND PURPOSE Promising results have been reported after volar locked plating of unstable dorsally displaced distal radius fractures. We investigated whether volar locked plating results in better patient-perceived, objective functional and radiographic outcomes compared to the less invasive external fixation. PATIENTS AND METHODS 63 patients under 70 years of age, with an unstable e...
متن کاملExtensor indicis proprius and extensor digitorum communis rupture after volar locked plating of the distal radius--a case report.
Distal radius fractures are among the most commonly encountered fractures in the extremities. Volar plating of distal radius fracture has gained popularity in recent years with the introduction of the locked plating system. Complications of volar plating include extensor and flexor tendon rupture. Here we present a case report of an extensor indicis proprius and extensor digitorum communis to i...
متن کاملCombined volar and dorsal plating for complex comminuted distal radial fractures.
PURPOSE To review outcomes of combined volar and dorsal locked plating for AO type-C3 complex comminuted distal radial fractures. METHODS Records of 24 patients aged 17 to 77 (mean, 53.3) years who underwent combined volar and dorsal locked plating for AO type-C3 distal radial fractures with volar and dorsal metaphyseal and intra-articular comminution were reviewed. 21 were closed fractures, ...
متن کاملComplications and Plate Removal Surgeries after Performing Volar Plating of Unstable Distal Radius Fractures
Complications have often been reported in the literature after distal radius fractures treated conservatively or operatively [1-3]. Previously, the main indication for volar plating was a volar Barton or Smith fracture, but now volar locking plates are the most commonly used treatment for unstable distal radius fractures and during the last decade this method has become increasingly popular [4]...
متن کاملFailure of volar locking plate fixation of an extraarticular distal radius fracture: A case report
BACKGROUND Volar locking plates provide significant structural stability to the distal radius. Failure of a volar locked plating is a rarely reported complication in the literature. CASE PRESENTATION A 40 year-old, obese female patient who presented with a displaced extraarticular distal radius fracture, underwent open reduction and internal fixation of the fracture using a volar locking plat...
متن کامل