Electrochemical Determination of Metronidazole in Tablet Samples Using Carbon Paste Electrode
نویسندگان
چکیده
Cyclic voltammetric investigation of metronidazole at carbon paste electrode revealed an irreversible reduction peak centered at about -0.4 V. Observed peak potential shift with pH in the range 2.0 to 8.5 indicated the involvement of protons during the reduction of metronidazole, whereas the peak potential shift with scan rate in the range 10-250 mV/s confirmed the irreversibility of the reduction reaction. A better correlation coefficient for the dependence of peak current on the scan rate than on the square root of scan rate indicated an adsorption controlled kinetics. Under the optimized method and solution parameters, an excellent linearity between the reductive peak current and the concentration of metronidazole was observed in the concentration range 1.0 × 10(-6) to 5.0 × 10(-4) M with a correlation coefficient, method detection limit (based on s = 3σ), and limit of quantification of 0.999, 2.97 × 10(-7) M and 9.91 × 10(-7) M, respectively. Good recovery results for spiked metronidazole in tablet samples and selective determination of metronidazole in tablet formulations in the presence of selected potential interferents such as rabeprazole, omeprazole, and tinidazole confirmed the potential applicability of the developed method for the determination of metronidazole in real samples like pharmaceutical tablets.
منابع مشابه
Voltammetric determination of glutathione in pharmaceutical and biological samples using multiwall carbon nanotubes paste electrode in the presence of rutin as a mediator
A new sensitive, selective and nonexpensive electrochemical sensor was developed for electrocatalyticdetermination of glutathione (GSH)in pharmaceutical and biological samples. GSH is a tripeptide thiol present in all eukaryotic and probiotic cells. A voltammetric studyof GSH has been carried out at the surface of carbon paste electrode modified with multiwall carbon nanotubes(MWCNTPE) in the p...
متن کاملVoltammetric determination of glutathione in pharmaceutical and biological samples using multiwall carbon nanotubes paste electrode in the presence of rutin as a mediator
A new sensitive, selective and nonexpensive electrochemical sensor was developed for electrocatalyticdetermination of glutathione (GSH)in pharmaceutical and biological samples. GSH is a tripeptide thiol present in all eukaryotic and probiotic cells. A voltammetric studyof GSH has been carried out at the surface of carbon paste electrode modified with multiwall carbon nanotubes(MWCNTPE) in the p...
متن کاملA Simple and an Effective Catalyst for Determination of Cefixime in Real Samples Using of Modified Carbon Paste Electrode with Cobalt Impregnated Zeolite
Carbon paste electrode modified with cobalt impregnated zeolite was prepared by mixing of cobalt_zeolite (Co_Z) and graphite powder with different percent. The electrochemical oxidation of cefixime at such electrodes was investigated using the cyclic voltammetric and amperometric techniques. It is not electrochemically active towards cefixime oxidation in 0.1 M phosphate buffer solution (pH=7) ...
متن کاملVoltammmetric Determination of Captopril Using Multiwall Carbon Nanotubes Paste Electrode in the Presence of Isoproterenol as a Mediator
The electrocatalytic oxidation of captopril (CAP) was studied by modified carbon nanotubes paste electrode in the presence of isoproterenol (ISPT) using cyclic voltammetry (CV), chronoamperometry and square wave voltammetry (SWV). Also, the values of catalytic rate constant (k), and electron transfer coefficient (α) for CAP were calculated. The mechanism of CA electrochemical behavior at the mo...
متن کاملVoltammmetric Determination of Captopril Using Multiwall Carbon Nanotubes Paste Electrode in the Presence of Isoproterenol as a Mediator
The electrocatalytic oxidation of captopril (CAP) was studied by modified carbon nanotubes paste electrode in the presence of isoproterenol (ISPT) using cyclic voltammetry (CV), chronoamperometry and square wave voltammetry (SWV). Also, the values of catalytic rate constant (k), and electron transfer coefficient (α) for CAP were calculated. The mechanism of CA electrochemical behavior at the mo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2016 شماره
صفحات -
تاریخ انتشار 2016