Concrete floor-bovine claw contact pressures related to floor roughness and deformation of the claw.

نویسندگان

  • A Franck
  • N De Belie
چکیده

The intention of this research was to study the impact of concrete floor surface roughness on a bovine claw model and to assess the deformation of the bovine claw model under load. The pressure distribution between the floor and the claw is the key method in this research. Monitoring foot-to-ground pressure distributions may provide insight into the relation between high local pressures and foot lesions. Concrete floor samples were made with 5 different finishing methods. Their roughness was determined by measuring the heights of the "peaks and the valleys" of the surface with a high-precision laser beam. The smoothest surface was the sample finished with a metal float (surface roughness R(a) = 0.062 mm) and the roughest surface occurred with the heavily sandblasted sample (surface roughness R(a) = 0.488 mm). The roughness of the concrete floor samples was related to the mean and peak contact pressures that can occur in a laboratory test bench between floor and bovine claw. It was found that the claw itself has approximately 2 times more effect on these contact pressures than the surface roughness. Peak pressures found were high enough (up to 111 MPa) to cause damage to the bovine claw sole horn. The strains occurring in the horn wall were measured and related to the floor-finishing method and the load. Strain gauge measurements indicated that it is difficult to predict what kind of deformation of the claw wall will occur at a certain location. Different strains will occur for different floor-finishing methods. The corresponding stresses in the horn wall did not exceed the yield stress (14 and 11 MPa for dorsal and abaxial wall horn, respectively).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Frictional Interactions between Bovine Claw and Concrete Floor

A. Franck; G. Opsomer; A. de Kruif; N. De Belie Magnel Laboratory for Concrete Research, Department of Structural Engineering, Faculty of Engineering, Ghent University, Technologiepark-Zwijnaarde 904, B-9052 Gent, Belgium; e-mail of corresponding author: [email protected] Department of Reproduction, Obstetrics, and Herd Health, Faculty of Veterinary Medicine, Ghent University, Salisburylaan...

متن کامل

Comparison of stress zones in finite element models of deformed bovine claw capsules.

Pathological claw formations occur subsequent to irregular or prolonged claw trimming periods and as a result of improper flooring. Clinical experience and material testing finds horn of minor quality to be associated with the malformations. Finite element models (FEM) of a flat claw (FC), a contracted claw (CC), and a laminitic claw (LC) were designed from native claw specimens to combine mate...

متن کامل

Roughness-dependent friction force of the tarsal claw system in the beetle Pachnoda marginata (Coleoptera, Scarabaeidae).

This paper studies slide-resisting forces generated by claws in the free-walking beetle Pachnoda marginata (Coleoptera, Scarabaeoidea) with emphasis on the relationship between the dimension of the claw tip and the substrate texture. To evaluate the force range by which the claw can interact with a substrate, forces generated by the freely moving legs were measured using a load cell force trans...

متن کامل

Effect of Flooring System on Locomotion Comfort in Dairy Cows: Aspects of Gait, Preference and Claw Condition

Telezhenko E. 2007. Effect of flooring system on locomotion comfort in dairy cows: aspects of gait, preference and claw condition. Doctor’s dissertation. ISSN 1652-6880, ISBN 978-91-576-7375-6 The aim of the thesis was to study influence of different flooring systems on several aspects of locomotion of dairy cows. To assess the gait on different floors, trackway analysis was used. Cows walking ...

متن کامل

Investigation of the Rigidity of Floor Diaphragms on the Behavior of Concrete Tall Buildings with Staggered Shear Walls under Lateral Loading

In most cases, structural engineers assume a concrete floor to be a rigid diaphragm. Although this simplification is in most cases acceptable, it should be noted that such an assumption may be distrusted due to certain problems. Concrete structures with staggered shear walls are among those whose analysis should be conducted with special concern for the behavior of their floor diaphragms. Howev...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of dairy science

دوره 89 8  شماره 

صفحات  -

تاریخ انتشار 2006